Victron MultiPlus Compact Manual

8. TECHNICAL DATA
MultiPlus
12/2000/80-50
120V
24/2000/50-50
120V
PowerControl / PowerAssist
Yes
Transfer switch (A)
50
Minimum PowerAssist current (A)
8,5
INVERTER
Input voltage range (V DC)
9,5 17 19 33
Output
Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25°C (VA) (3)
2000
Cont. output power at 25°C (W)
1600
Cont. output power at 40°C (W)
1450
Peak power (W)
4000
Maximum efficiency (%)
92
94
Zero-load power (W)
9
11
Zero load power in search mode (W)
3
4
CHARGER
AC Input
Input voltage range: 95-140 VAC
Input frequency: 45 65 Hz Power factor: 1
Charge voltage 'absorption' (V DC)
14,4 / 28,8
28,8
Charge voltage 'float' (V DC)
13,8 / 27,6
27,6
Storage mode (V DC)
13,2 / 26,4
26,4
Charge current house battery (A) (4)
80
50
Charge current starter battery (A)
4
Battery temperature sensor
yes
GENERAL
Programmable relay (5)
yes
Protection (2)
a - g
Common Characteristics
Operating temp. range: -40 - +40°C (fan assisted
cooling) Humidity (non condensing) : max 95%
ENCLOSURE
Common Characteristics
Material & Colour: aluminium (blue RAL 5012)
Protection category: IP20
Battery-connection
Bolts M8
120 V AC-connection
screw-terminals 6 AWG (13mm²)
Weight (lbs)
25 (13 kg)
Dimensions (hxwxd in inches)
20.5 x 10.0 x 5.0 (520 x 255 x 125 mm)
STANDARDS
Safety
EN 60335-1, EN 60335-2-29, UL 458
Emission / Immunity
EN 55014-1, EN 55014-2, EN 61000-3-3