Victron MultiPlus Datasheet

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
MultiPlus
12 Volt
24 Volt
12/2000/80
24/2000/50
12/3000/120
24/3000/70
PowerControl
Yes
PowerAssist
Yes
Transfer switch (A)
50
Parallel and 3-phase operation
Yes
INVERTER
Input voltage range (V DC)
9,5 17 V 19 33 V
Output
Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25ºC / 77°F (VA) (3)
2000
3000
Cont. output power at 25ºC / 77°F (W)
1600
2400
Cont. output power at 40ºC / 104°F (W)
1450
2200
Cont. output power at 65ºC / 150°F (W)
1100
1700
Peak power (W)
4000
6000
Maximum efficiency (%)
92 / 94
93 / 94
Zero load power (W)
9 / 11
20 / 20
Zero load power in AES mode (W)
7 / 8
15 / 15
Zero load power in Search mode (W)
3 / 4
8 / 10
CHARGER
AC Input
Input voltage range: 95-140 VAC Input frequency: 45 65 Hz Power factor: 1
Charge voltage 'absorption' (V DC)
14,4 / 28,8
Charge voltage 'float' (V DC)
13,8 / 27,6
Storage mode (V DC)
13,2 / 26,4
Charge current house battery (A) (4)
80 / 50
120 / 70
Charge current starter battery (A)
4
Battery temperature sensor
yes
GENERAL
Auxiliary output (5)
n. a.
Yes (32A)
Programmable relay (6)
Yes (1x)
Yes (3x)
Protection (2)
a - g
VE.Bus communication port
For parallel and three phase operation, remote monitoring and system integration
General purpose com. port (7)
n. a.
Yes (2x)
Remote on-off
Yes
Common Characteristics
Operating temp. range: -40 - +65°C / -40 to 150°F (fan assisted cooling) Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics
Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection
M8 bolts
M8 bolts (2 plus and 2 minus connections)
120 V AC-connection
Screw-terminal 6 AWG (13 mm²)
Screw-terminal 6 AWG (13mm²)
Weight
13 kg 25 lbs.
19kg 40 lbs.
Dimensions (hxwxd in mm and inches)
520x255x125 mm 20.5x10.0x5.0 inch
362x258x218 mm 14.3x10.2x8.6 inch
STANDARDS
Safety
UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
UL 1741, UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
Emission and Immunity
EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3
EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3
1) Can be adjusted to 50 HZ;
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 120 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 75˚F ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general
alarm,
DC under voltage or genset start/stop function
AC rating: 120 V/4 A
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
7) A.o. to communicate with a Lithium Ion battery BMS
Computer controlled operation and monitoring
Several interfaces are available:
Digital Multi Control
A convenient and low cost solution for
remote monitoring, with a rotary knob to set
PowerControl and PowerAssist levels.
VE.Bus Smart Dongle
Measures battery voltage
and temperature and allows
monitoring and control of
Multis and Quattros with a
smartphone or other
Bluetooth enabled device
.
Color Control GX and other GX devices
Provides monitor and control. Locally, and also
remotely on the VRM Portal.
MK3-USB VE.Bus to USB interface
Connects to a USB port (see ‘A guide to
VEConfigure’)
VE.Bus to NMEA 2000 interface
Connects the device to a NMEA2000 marine
electronics network. See the NMEA2000 &
MFD integration guide
BMV-712 Smart Battery
Monitor
Use a smartphone or other
Bluetooth enabled device to:
- customize settings,
- monitor all important data on
single screen,
- view historical data, and to
update the software when new
features become available.