MultiPlus-II 12/3000/120-50 2x120V Data Sheet
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Cerbo GX with GX Touch 50
Provides intuitive system control and monitoring
Besides system monitoring and control the Cerbo enables access to
our free remote monitoring website: the VRM Online Portal
VRM app
Monitor and manage your
Victron Energy system from
your smart phone and
tablet. Available for both
iOS and Android.
VRM Portal
Our free remote monitoring website (VRM) will display all
system data in a comprehensive graphical format. System
settings can be changed remotely via the portal. Alarms can be
received by e-mail.
Current sensor 100A:50mA
To implement PowerControl and
PowerAssist and to optimize self-
consumption with external current
sensing.
Maximum current: 50A resp. 100A.
MultiPlus-II 2x120V 12/3000/120-50 24/3000/70-50
PowerControl & PowerAssist
Yes (on L1 input)
Transfer switch
50 A
Maximum AC input current
50A (each leg)
INVERTER
DC Input voltage range
9,5 – 17 V
19-33V
Output when in inverter mode
Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25°C (3)
3000 VA
Cont. output power at 25°C
2400 W
Cont. output power at 40°C
2200 W
Cont. output power at 65°C
1700 W
Maximum apparent feed-in power
2500 VA
Peak power
5500 W
Maximum efficiency
93%
94%
Zero load power
15W
11W
Zero load power in AES mode
10W
8W
Zero load power in Search mode
4W
4W
CHARGER
AC Input
Split phase: 180-280 VAC 45 – 65 Hz
Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage 'absorption'
14,4 V
28,8 V
Charge voltage 'float'
13,8 V
27,6 V
Storage mode
13,2 V
26,4 V
Maximum battery charge current (4)
120 A
70 A
Battery temperature sensor
Yes
GENERAL
Auxiliary output (5)
50 A (each leg) See note 8
External AC current sensor (optional)
100 A
Programmable relay (6)
Yes
Protection (2)
a – g
VE.Bus communication port
For parallel and three phase operation,
remote monitoring and system integration
General purpose com. Port (7)
Yes, 2x
Remote on-off
Yes
Operating temperature range
-40 to +65°C (-40 -150°F) Fan assisted cooling
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour
Steel, blue RAL 5012
Protection category
IP22
Battery-connection
2x2 M8 bolts
2 M8 bolts
120/240 V AC-connection
Screw terminals 21 mm² (4 AWG)
Weight
22 kg (48 lb)
Dimensions (hxwxd)
578 x 275 x 148 mm
(23 x 11 x 6 inch)
578 x 275 x 148 mm
(23 x 11 x 6 inch)
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458
Emission, Immunity
EN 55014-1, EN 55014-2
EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
1) Can be adjusted to 50 Hz
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 120 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 75 ˚ F / 25 ˚ C ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general alarm,
DC under voltage or genset start/stop function
AC rating: 120 V/4 A
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
7) A. o. to communicate with a Lithium-Ion battery BMS
8) The auxiliary output of an early production batch of this
product was rated at 35A instead of 50A. This batch has serial
numbers starting with HQ2107. Later batches, with 50A aux.
output have serial numbers starting with HQ2114 or higher.
Digital Multi Control Panel
A convenient and low-cost solution for remote
monitoring, with a rotary knob to set
PowerControl and PowerAssist levels.
VE.Bus Smart Dongle
Measures battery voltage and
temperature and allows
monitoring and control with a
smart phone or other
Bluetooth enabled device.
Connection Area