User manual

Voltage compensation
Diode splitter
traction battery
+ 0.6V through jumper
+ 2.0V through jumper
Output voltage alarm 5A potential free contact
Output current:
Skylla 24/25
Skylla 24/50
Skylla 24/75
Skylla 24/100
25A
50A
75A
100A
Output current ripple: 70% rms at full load
Output current stability: +/- 5 %
Short circuit protection: Continuous short circuit proof
8.3 General:
Radio interference suppression: EN55014
Electromagnetic compatibility: IE801-2 class 3
IE801-3 class 2
IE801-4 class 2 for the output
IE801-4 class 3 for the input
IE801-5 class 3
Safety: IE335-2-29
8.4 Environment:
Temperature range:
-10 to 50ºC. The charge current
decreases if the temperature
rises above 40ºC
Cooling: Natural cooling