2. TROUBLESHOOTING
2.1 The flash sequence table
Your Phoenix inverter is equipped with a self-diagnosis system, to
inform you about the cause of inverter shut down
In the table below you can find out what kind of flashing sequence
belongs to which error.
LED Status
Solid green
OK
Red, blinking fast
−
−
−
−
−
−
−
−
Over voltage
Red, blinking slow
Under voltage
Red, intermittent blinking
−
−
−
−
−
−
Over temperature
Solid red
Overload
2.2 Troubleshooting guidelines
PROBLEM : Inverter is not working (LED OFF)
Possible cause :
Remedy :
Power switch in OFF position. Push the power switch to the ON
position.
Poor contact between the
inverter’s battery wires and the
battery terminals.
Clean battery terminals or inverter
wire contacts. Tighten battery
terminal screws.
Blown inverter fuse. The inverter has to be returned for
service.
Very poor battery condition. Replace battery.