PROBLEM : ‘Inverter temperature too high. Cooling down’ error
keeps on appearing
Possible cause : Remedy :
Airflow around the inverter is
obstructed.
Make sure there is at least 10
centimetres of clearance around
the inverter. Remove any items
placed on or over the inverter.
Keep the inverter away from direct
sunlight or heat producing
equipment.
Too high ambient temperature. Move the inverter to a cooler place
or provide additional cooling by an
external fan.
Note: Don’t turn-off the inverter when it’s operating in an ‘Inverter
temperature too high. Cooling down’ error. The inverter needs this
error time to cool down.
If none of the above remedies helps to solve the problem you encounter,
contact your local Victron Energy distributor for further help and/or
possible repair of your inverter. Do not open the inverter yourself, there
are dangerous high voltages present inside. Opening the inverter will
directly void your 12 months warranty period.