User manual

14 manual
victron energy
victron energyvictron energy
victron energy
3. TECHNICAL DATA
Note : the given specifications are subject to change without notice
3.3 Enclosure dimensions Ph xx/150, Ph 12/301
See page 71.
Phoenix Inverter
12 Volt
24 Volt
48 Volt
12/180
24/180
48/180
12/350
24/350
48/350
Cont. AC power at 25 °C (VA)
(3)
180 350
Cont. power at 25 °C / 40 °C (W) 175 / 150 300 / 250
Peak power (W) 350 700
Output AC voltage / frequency 110VAC or 230VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range (V DC) 10,5 - 15,5 / 21,0 - 31,0 / 42,0 - 62,0
Low battery alarm (V DC) 11,0 / 22 / 44
Low battery shut down (V DC) 10,5 / 21 / 42
Low battery auto recovery (V DC) 12,5 / 25 / 50
Max. efficiency 12 / 24 / 48 V (%) 87 / 88 / 89 89 / 89/ 90
Zero-load power 12 / 24 / 48 V (W) 2,6 / 3,8 / 4,0 3,1 / 5,0 / 6,0
Zero-load power in Power Saving mode
n. a. n. a.
Protection
(2)
a - e
Operating temperature range -20 to +50°C (fan assisted cooling)
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue Ral 5012)
Battery-connection 1) 1)
Standard AC outlets IEC-320 (IEC-320 plug included), Schuko, or Nema 5-15R
Other outlets (at request) United Kingdom, Australia/New Zealand
Protection category IP 20
Weight (kg / lbs) 2,7 / 5,4 3,5 / 7,7
Dimensions (hxwxd in mm)
(hxwxd in inches)
72x132x200
2.8x5.2x7.9
72x155x237
2.8x6.1x9.3
ACCESSORIES
Remote control panel n. a. n. a.
Remote on-off switch Two pole connector
Automatic transfer switch Filax
STANDARDS
Safety EN 60335-1
Emission / Immunity EN55014-1 / EN 55014-2
1) Battery cables of 1.5 meter (12/180 with cigarette plug)
2) Protection
a.
Output short circuit
b.
Overload
c.
Battery voltage too high
d.
Battery voltage too low
e.
Temperature too high
3) Non linear load, crest factor 3:1