Technical information
35
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
Phoenix Charger 12/30 12/50 24/16 24/25
Input voltage range (V AC) 90-265
Input voltage range (V DC) 90-400
Frequency (Hz) 45-65
Power factor 1
Charge voltage 'absorption' (V DC) 14,4 14,4 28,8 28,8
Charge voltage 'float' (V DC) 13,8 13,8 27,6 27,6
Storage mode (V DC) 13,2 13,2 26,4 26,4
Charge current house batt. (A) (2) 30 50 (3) 16 25 (3)
Charge current starter batt. (A) 4 4 4 4
Charge characteristic 4 stage adaptive
Battery capacity (Ah) 100-400 200-800 100-200 100-400
Temperature sensor √ √ √ √
Can be used as power supply √ √ √ √
Forced cooling √ √ √ √
Protection (1) a,b,c,d
Operating temp. range -20 to 60°C (0 - 140°F)
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Battery-connection M6 studs
AC-connection screw-clamp 4 mm (AWG 6)
Protection category IP 21
Weight kg (lbs) 3,8 (8)
Dimensions (hxwxd in mm and inches) 350x200x108 mm (13.8x7.9x4.3 inch)
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-3-2,
Automotive Directive EN 55014-2, EN 61000-3-3
Vibration IEC68-2-6:10-150Hz/1.0G
1) Protection key:
a) Output short circuit
b) Battery reverse polarity detection
c) Battery voltage too high
d) Temperature too high
2) Up to 40 °C (100 °F) ambient
Battery Alarm
An excessively high or low battery
voltage is indicated by an audible
and visual alarm, and potential free
contacts.
Phoenix Charger Control
The PCC panel provides remote control
and monitoring of the charge process
with LED indication of the charger status.
In addition, the remote panel also offers
output current adjustment that can be
used to limit the output current and thus
the power drawn from the AC supply.
This is particularly useful when operating
the charger from limited shore power or
small gensets. The panel can also be used
to change the battery charging
parameters.
The brightness of the LED’s is
automatically reduced during night time.
Connection to the charger is with a
standard UTP – cable.
Computer controlled operation
and monitoring
(Victron Interface MK2)
Every Phoenix Charger is ready to
communicate with a computer through
its RS-485 data port. All you need to link
to your PC and be able to set and read
out all parameters is the data link as
shown.
Moreover, all Victron Energy products
equipped with an RS-485 data port can
easily be integrated in VENet, the power
control network of Victron Energy, or to
other computerised monitoring and
control systems.
BMV 600 Battery Monitor
The BMV 600 Battery Monitor features an
advanced microprocessor control system
combined with high resolution
measuring systems for battery voltage
and charge/discharge current. Besides
this, the software includes complex
calculation algorithms, like Peukert’s
formula, to exactly determine the state of
charge of the battery. The BMV 600
selectively displays battery voltage,
current, consumed Ah or time to go.
PHOENIX BATTERY CHARGER 12/24V