Technical information
63
GEL AND AGM BATTERIES
www.victronenergy.com
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
15. Charge current
The charge current should preferably not exceed 0,2 C (20 A for a 100 Ah battery).The temperature of a battery will increase by more than 10°C if the charg
e
current exceeds 0,2 C. Therefore temperature compensation is required if the charge current exceeds 0,2 C
Float
service
Cycle service
Normal
Cycle service
Fastest recharge
Victron AGM “Deep Cycle”
Absorbtion 14,2 - 14,6 14,6 - 14,9
Float 13,5 - 13,8 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5 13,2 - 13,5
Victron Gel “Deep Cycle”
Absorbtion 14,1 - 14,4
Float 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5
Victron Gel “Long Life”
Absorbtion 14,0 - 14,2
Float 13,5 - 13,8 13,5 - 13,8
Storage 13,2 - 13,5 13,2 - 13,5
12 Volt Deep Cycle AGM
General Specification
Article number Ah V
l x w x h
mm
Weight
kg
CCA
@0°F
RES CAP
@80°F
Technology: flat plate AGM
Terminals: copper
BAT406225080 240
6 320x176x247 31 1500 480
Rated capacity: 20 hr discharge at 25°C
Float design life: 7-10 years at 20 °C
Cycle design life:
200 cycles at 100% discharge*
400 cycles at 50% discharge
900 cycles at 30% discharge
BAT212070080 8
12 151x65x101 2,5
BAT212120080 14 12 151x98x101 4,1
BAT212200080 22
12 181x77x167 5,8
BAT412350080 38 12 197x165x170 12,5
BAT412550080 60
12 229x138x227 20 450 90
BAT412600080 66
12 258x166x235 24 520 100
BAT412800080 90
12 350x167x183 27 600 145
BAT412101080 110
12 330x171x220 32 800 190
BAT412121080 130 12 410x176x227 38 1000 230
BAT412151080 165
12 485x172x240 47 1200 320
BAT412201080 220
12 522x238x240 65 1400 440
12 Volt Deep Cycle GEL
General Specification
Article number Ah V
l x w x h
mm
Weight
kg
CCA
@0°F
RES CAP
@80°F
Technology: flat plate GEL
Terminals: copper
BAT412550100 60
12 229x138x227 20 300 80
Rated capacity: 20 hr discharge at 25 °C
Float design life: 12 years at 20 °C
Cycle design life:
300 cycles at 100% discharge *
600 cycles at 50% discharge
1300 cycles at 30% discharge
BAT412600100
66
12 258x166x235 24 360 90
BAT412800100
90 12 350x167x183 26 420 130
BAT412101100
110
12 330x171x220 33 550 180
BAT412121100
130
12 410x176x227 38 700 230
BAT412151100
165
12 485x172x240 48 850 320
BAT412201100
220
12 522x238x240 66 1100 440
2 Volt Long Life GEL
General Specification
Article number Ah V
l x b x h
mm
Weight
kg
Technology: tubular plate GEL
Terminals: copper
BAT702601260 600 2 149x208x710 48
Rated capacity: 10 hr discharge at 25 °C
Float design life: 20 years at 20 °C
Cycle design life:
1200 cycles at 100% discharge *
1200 cycles at 50% discharge
2400 cycles at 30% discharge
BAT702801260 800
2 215x193x710 68
BAT702102260
1000
2 215x235x710 82
BAT702122260
1200
2 215x277x710 94
BAT702152260
1500
2 215x277x855 120
BAT702202260
2000 2 215x400x815 160
BAT702252260
2500
2 215x490x815 200
BAT702302260
3000 2 215x580x815 240
Table 3: Recommended charge voltage
Other capacities and terminal types: at request