Datasheet

www.victronenergy.com
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
Argo FET Battery Isolator Argofet 100-2 Argofet 100-3 Argofet 200-2 Argofet 200-3
Maximum charge current (A) 100 100 200 200
Maximum alternator current (A) 100 100 200 200
Number of batteries 2 3 2 3
Connection M8 bolts M8 bolts M8 bolts M8 bolts
Weight kg (lbs) 1,4 (3.1) 1,4 (3.1) 1,4 (3.1) 1,4 (3.1)
Dimensions h x w x d in mm
(h x w x d in inches)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more
batteries from one alternator (or a single output battery charger), without connecting the batteries
together. Discharging the accessory battery for example will not result in also discharging the
starter battery.
In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is
less than 0,02 Volt at low current and averages 0,1 Volt at higher currents.
When using ARGO FET Battery Isolators, there is no need to also increase the output voltage of the
alternator. Care should taken however to keep cable lengths short and of sufficient cross section.
Example:
When a current of 100 A flows through a cable of 50 mm cross section (AWG 0) and 10 m length
(30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly a current of 50 A through a cable
of 10 mm cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 Volt!
Alternator energize input
Some alternators need DC voltage on the B+ output to start charging. Obviously, DC will be present
when the alternator is directly connected to a battery. Inserting a Diode or FET splitter will however
prevent any return voltage/current from the batteries to the B+, and the alternator will not start.
The new Argofet isolators have a special current limited energize input that will power the B+ when
the engine run/stop switch is closed.
ARGO
FET
Battery Isolators
With alternator energize input
FET
100
-
3
3bat 100A
FET
100
-
3
3bat 100A

Summary of content (1 pages)