Data Sheet
Table Of Contents
2021-02-19 10:03 1/2 Temperature Sensors
Victron Energy - https://www.victronenergy.com/live/
Temperature Sensors
Victron products can make use of temperature sense information to improve accuracy of battery
charging. There is a range of various sensors that you can use depending on your product. Some
come included, others can be purchased separately. See the datasheet if the required product (eg
Multi, Quattro, BMV) to know if the sensor comes included.
Temperature
Sensor
VE.Bus Smart
Dongle (1)
Smart Battery
Sense (3M)
Smart
Battery Sense
(10M)
Temp.
Sensor for
Quattro,
MulitPlus &
GX Device
Temp. Sensor for BMV Temp. sensor type C
Picture
Products
Supported
MultiPlus-II, VE.Bus
devices
Bluetooth enabled
VE.Direct MPPTs
and Phoenix
Smart IP43
Charger
Bluetooth
enabled
VE.Direct
MPPTs and
Phoenix Smart
IP43 Charger
MultiPlus,
Quattro,
Compatible GX
devices (Cerbo
GX, Venus GX,
etc), VE.Can
MPPT, Skylla-S,
Sylla-TG and
Skylla-i
Battery Monitors with Temp
Support - eg BMV-702 & 712,
SmartShunt & VE.Bus Smart
Dongle
Inverter RS Smart Solar
Victron Part
Number
ASS030537010 SBS050100200 SBS050150200 ASS000001000 ASS000100000 ASS000020000
Temperature
on VRM
Yes No No
MultiPlus - Yes,
Venus GX -
Yes, VE.Can
MPPT - Yes
Yes No
Product Page Link Link Link Link Link tbd
Manual Accessory Manual Accessory Manual
Accessory
Manual
See Inverter /
Charger /
Device Product
Manual
See Battery Monitor Product
Manual
See Inverter RS Smart Solar Manual
VE.Smart
Networking
No Yes Yes No
Yes with BMV-712; Yes with
dongle for BMV-702
No
Modifying
cable length?
n/a yes (2) yes (2) yes (2) yes (3) yes (2)
Notes:
You can mount the dongle itself directly on the battery. It has an internal temperature1.
measurement. There are also terminals you can connect an external probe to as well, you must
use the probe part - ASS000100000.
Cable length may be altered without any issue - within reason. The same wiring is used as a2.
power supply for the Smart Battery Sense as well, too much resistance in the cabling will cause
a too low voltage reading. If desired, cable length may be shortened without any issue.
Although discouraged and unsupported, cable length may also be extended if necessary for the3.
installation - providing the additional length is kept short and conductor cross section is
sufficient, a slight increase in cable resistance will not negatively effect the temperature
reading accuracy. Note that a notable increase in cable resistance to the BMV temperature
sensor will also effect the voltage reading accuracy.