Installation
2019-08-15 12:22 19/39 Color Control GX manual
Victron Energy - https://www.victronenergy.com/live/
VRM Portal FAQ - difference between BMV SOC and VE.Bus SOC
CCGX Manual - configurable parameters. See Battery Monitor selection and Has DC System.
2.4.4 Selecting SOC source
(Settings → System Setup → Battery monitor)
In the image below you can see a range of selectable choices for the SOC values which are shown in
the main Overview screen. Choose the source you want to see on the main Overview screen of your
CCGX.
In the image above we have chosen the Automatic setting. When automatic is selected the System
setup screen will be as shown in the image below.
The 'Automatic' function uses the following logic:
When available, it will use a dedicated Battery Monitor, such as the BMV or a Lynx Shunt, or a1.
battery with built-in battery monitor.
When there is more than one of those connected, it will use a random one - although you can2.