Trouble shooting tips:
Make sure that basic communication with VRM works, see chapter 5.4.1.
After enabling the feature, make sure to set (or disable) the password.2.
Also make sure to restart the CCGX.3.
Make sure to update the CCGX to the latest firmware version. The last stability improvement for4.
Remote Console was made in version v2.30.
After the restart, check the Remote Console on VRM status shows online or a port number. In5.
case it says offline, or port number 0, the CCGX was unable to connect to the Remote Console
server. This is normally caused by a (company) firewall, blocking the connection. The solution is
then to configure an exception rules in the firewall.
Verify that your local web browser can access the websocket port (443 on6.
vncrelay.victronenergy.com). If you click that link and get 'Error response, method not allowed',
it means the connection between your PC and the VNC relay is working. If you get a timeout or
another (browser) error, there may be a firewall blocking the connection.
Remote Console on VRM uses the same reverse SSH tunnel as is used for Remote Support: outbound
connection to supporthost.victronenergy.com on port 22, 80 or 443. It is not necessary to set up port
forwarding in routers to use Remote Console on VRM. It is necessary for the firewall/router to which
the CCGX is connected, to allow outbound connections to supporthost.victronenergy.com on at least
one of the three mentioned port numbers. Most routers will allow this by default.