GX Touch 50 Wall Mount Manual

Table Of Contents
2.9. Connecting Temperature Sensors
See the Connection Overview [2] for the location and number of temperature sensors.
They can be used to measure & monitor all kinds of temperature-inputs.
Temperature senders are not included. The required sensor is ASS000001000 - Temperature Sensor QUA/PMP/Venus GX.
(Note that this is different to the BMV temperature accessory.)
They are not required to be connected to the battery (though they appear like a battery lug).
Sensors are enabled (and disabled) in the I/O menu of the GX device settings. Once enabled, they will appear in the device list
menu.
Temperature setting can be configured as Battery, Fridge or Generic. It is also possible to set a custom name in the device menu.
It is possible to adjust the temperature offset and scale.
Once enabled, temperature sensor data is visible in the device list, and also logged to VRM.
To physically attach the temperature probes requires a ferrule or exposed copper end of at least 10 mm+ to be inserted into the
removable terminal block connector. Once correctly attached, you must push in the orange tab if you wish to remove the secured
wire.
2.10. Connecting IMT Solar Irradiance, Temperature and Wind Speed Sensors
Compatibility
Ingenieurbüro Mencke & Tegtmeyer GmbH (IMT) offer a range of digital silicon irradiance sensor models within the Si-RS485
series that are all compatible with a Victron GX device.
The optional/additional external module temperature, ambient temperature and wind speed sensors are also supported.
Optional/additional external sensors are either connected to the solar irradiance sensor with pre-installed plugs or pre-wired to the
solar irradiance sensor (external module and ambient temperature only). When external sensors are connected via an
appropriate solar irradiance sensor, all measurement data is transmitted to the Victron GX device with the single interface cable.
Each model solar irradiance sensor within Si-RS485 series has a different capability with regards to external sensors (or comes
with an external sensor pre-wired), so carefully consider any future desires/requirements before initial purchase.
It is also possible to connect an independent IMT Tm-RS485-MB module temperature sensor (visible as ‘cell temperature’) or IMT
Ta-ext-RS485-MB ambient temperature sensor (visible as ‘external temperature’) directly to the Victron GX device, without a solar
irradiance sensor or in addition to one.