GX Touch 50 Wall Mount Manual
Table Of Contents
- Cerbo GX Manual
- Table of Contents
- 1. Introduction
- 2. Installation
- 2.1. Overview of connections
- 2.2. Power
- 2.3. Connecting Victron products
- 2.3.1. Multis/Quattros/Inverters (VE.Bus products)
- 2.3.2. Battery Monitor BMV-700 series; and MPPTs with a VE.Direct port
- 2.3.3. Skylla-i, Lynx Shunt VE.Can, Lynx Ion + Shunt and MPPTs with a VE.Can port
- 2.3.4. VE.Can and BMS-Can Interfaces
- 2.3.5. BMV-600 series
- 2.3.6. DC Link box
- 2.3.7. VE.Can Resistive Tank Sender Adapter
- 2.4. Connecting a PV Inverter
- 2.5. Connecting a USB GPS
- 2.6. Connecting a Fischer Panda Generator
- 2.7. Connecting Tank Level Sensors
- 2.8. Connecting third-party NMEA 2000 tank senders
- 2.9. Connecting Temperature Sensors
- 2.10. Connecting IMT Solar Irradiance, Temperature and Wind Speed Sensors
- 3. Internet connectivity
- 3.1. Ethernet LAN port
- 3.2. Wi-Fi
- 3.3. GX GSM
- 3.4. Mobile (cellular) network using a 3G or 4G router
- 3.5. USB tethering using a mobile phone
- 3.6. IP Configuration
- 3.7. Connecting both Ethernet and Wi-Fi (failover)
- 3.8. Minimize internet traffic
- 3.9. More information about setting up an internet connection and VRM
- 4. Accessing the GX device
- 5. Configuration
- 6. GX - How to update firmware
- 7. VE.Bus Inverter/charger monitoring
- 8. DVCC - Distributed Voltage and Current Control
- 9. VRM Portal
- 10. Marine MFD integration by App
- 11. Marine MFD integration by NMEA2000
- 12. Digital Inputs
- 13. GX - Generator auto start/stop
- 14. Error Codes
- 15. FAQ
- 15.1. Q1: I cannot switch my Multi/Quattro system on or off
- 15.2. Q2: Do I need a BMV to see proper battery state of charge?
- 15.3. Q3: I have no internet, where can I insert a sim-card?
- 15.4. Q4: Can I connect both a GX Device and a VGR2/VER to a Multi/Inverter/Quattro?
- 15.5. Q5: Can I connect multiple Cerbo GX to a Multi/Inverter/Quattro?
- 15.6. Q6: I see incorrect current (amps) or power readings on my Cerbo GX
- 15.7. Q7: There is a menu entry named "Multi" instead of the VE.Bus product name
- 15.8. Q8: There is a menu entry named "Multi", while there is no Inverter, Multi or Quattro connected
- 15.9. Q9: When I type the ip-address of the Cerbo GX into my browser, I see a web page mentioning Hiawatha?
- 15.10. Q10: I have multiple Solar chargers MPPT 150/70 running in parallel. From which one will I see the relay status in the Cerbo GX menu?
- 15.11. Q11: How long should an automatic update take?
- 15.12. Q12: I have a VGR with IO Extender, how can I replace this with a Cerbo GX?
- 15.13. Q13: Can I use Remote VEConfigure, as I was doing with the VGR2?
- 15.14. Q14: The Blue Power Panel could be powered through the VE.Net network, can I also do that with a Cerbo GX?
- 15.15. Q15: What type of networking is used by the Cerbo GX (TCP and UDP ports)?
- 15.16. Q16: What is the functionality behind the menu item Remote support (SSH), in the Ethernet menu?
- 15.17. Q17: I don’t see support for VE.Net products in the list, is that still coming?
- 15.18. Q18: What is the data usage of the Cerbo GX?
- 15.19. Q19: How many AC Current Sensors can I connect in one VE.Bus system?
- 15.20. Q20: Issues with Multi not starting when Cerbo GX is connected / Caution when powering the Cerbo GX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro
- 15.21. Q21: I love Linux, programming, Victron and the Cerbo GX. Can I do more?
- 15.22. Q22: How do I change the logo
- 15.23. Q23: Multi restarts all the time (after every 10sec)
- 15.24. Q24: What is Error #42?
- 15.25. GPL Note
- 16. More information
Table 1.
Setting Default Description
CAN-bus Profile VE.Can Defines the type & baudrate of the CAN-bus network. To use in combination
with NMEA2000, make sure to choose one of the profiles that include
VE.Can and is at 250kbit/s
NMEA2000-out Off Enables and disabled the NMEA2000-out function
Unique identity number selector 1 Selects the block of numbers to use for the NAME Unique Identity Numbers
in the PGN 60928 NAME field. For the GX Device itself, and when
NMEA2000-out is enabled, also for the virtual-devices. Change it only when
installing multiple GX Devices in the same VE.Can network. There are no
other reasons to change this number. For more details regarding the Unique
identity number, read the last section in this chapter.
Check unique numbers Searches for other devices that use the same unique number. When the
search is completed it will respond with either an OK, or the text :
There is another device connected with this unique number, please select
another one.
Note that there is normally no reason to use this function: the GX Device
automatically and continuously checks uniqueness of the numbers in use,
and will warn when in case there is a conflict. This setting is made available
to quickly confirm that everything is OK after changing the setting.
11.4. NMEA2000 Configuring device instances
The Devices submenu gives access to a list showing all detected Devices on the VE.Can / NMEA-2000 network:
Each entry first shows the name - either the product name as in our database, or when configured, the custom name as
configured during installation.
Then, between the square brackets, the Unique Identity Number is shown.
On the right, you can see the VE.Can Device Instance which is the same as the NMEA-2000 Device Instance.
Press enter to Edit that Device Instance. Or, press the right-key to go one step deeper in the menu structure, to a page that
shows all generic data available for that device:
Cerbo GX Manual
Page 57 Marine MFD integration by NMEA2000