GX Touch 50 Wall Mount Manual
Table Of Contents
- Cerbo GX Manual
- Table of Contents
- 1. Introduction
- 2. Installation
- 2.1. Overview of connections
- 2.2. Power
- 2.3. Connecting Victron products
- 2.3.1. Multis/Quattros/Inverters (VE.Bus products)
- 2.3.2. Battery Monitor BMV-700 series; and MPPTs with a VE.Direct port
- 2.3.3. Skylla-i, Lynx Shunt VE.Can, Lynx Ion + Shunt and MPPTs with a VE.Can port
- 2.3.4. VE.Can and BMS-Can Interfaces
- 2.3.5. BMV-600 series
- 2.3.6. DC Link box
- 2.3.7. VE.Can Resistive Tank Sender Adapter
- 2.4. Connecting a PV Inverter
- 2.5. Connecting a USB GPS
- 2.6. Connecting a Fischer Panda Generator
- 2.7. Connecting Tank Level Sensors
- 2.8. Connecting third-party NMEA 2000 tank senders
- 2.9. Connecting Temperature Sensors
- 2.10. Connecting IMT Solar Irradiance, Temperature and Wind Speed Sensors
- 3. Internet connectivity
- 3.1. Ethernet LAN port
- 3.2. Wi-Fi
- 3.3. GX GSM
- 3.4. Mobile (cellular) network using a 3G or 4G router
- 3.5. USB tethering using a mobile phone
- 3.6. IP Configuration
- 3.7. Connecting both Ethernet and Wi-Fi (failover)
- 3.8. Minimize internet traffic
- 3.9. More information about setting up an internet connection and VRM
- 4. Accessing the GX device
- 5. Configuration
- 6. GX - How to update firmware
- 7. VE.Bus Inverter/charger monitoring
- 8. DVCC - Distributed Voltage and Current Control
- 9. VRM Portal
- 10. Marine MFD integration by App
- 11. Marine MFD integration by NMEA2000
- 12. Digital Inputs
- 13. GX - Generator auto start/stop
- 14. Error Codes
- 15. FAQ
- 15.1. Q1: I cannot switch my Multi/Quattro system on or off
- 15.2. Q2: Do I need a BMV to see proper battery state of charge?
- 15.3. Q3: I have no internet, where can I insert a sim-card?
- 15.4. Q4: Can I connect both a GX Device and a VGR2/VER to a Multi/Inverter/Quattro?
- 15.5. Q5: Can I connect multiple Cerbo GX to a Multi/Inverter/Quattro?
- 15.6. Q6: I see incorrect current (amps) or power readings on my Cerbo GX
- 15.7. Q7: There is a menu entry named "Multi" instead of the VE.Bus product name
- 15.8. Q8: There is a menu entry named "Multi", while there is no Inverter, Multi or Quattro connected
- 15.9. Q9: When I type the ip-address of the Cerbo GX into my browser, I see a web page mentioning Hiawatha?
- 15.10. Q10: I have multiple Solar chargers MPPT 150/70 running in parallel. From which one will I see the relay status in the Cerbo GX menu?
- 15.11. Q11: How long should an automatic update take?
- 15.12. Q12: I have a VGR with IO Extender, how can I replace this with a Cerbo GX?
- 15.13. Q13: Can I use Remote VEConfigure, as I was doing with the VGR2?
- 15.14. Q14: The Blue Power Panel could be powered through the VE.Net network, can I also do that with a Cerbo GX?
- 15.15. Q15: What type of networking is used by the Cerbo GX (TCP and UDP ports)?
- 15.16. Q16: What is the functionality behind the menu item Remote support (SSH), in the Ethernet menu?
- 15.17. Q17: I don’t see support for VE.Net products in the list, is that still coming?
- 15.18. Q18: What is the data usage of the Cerbo GX?
- 15.19. Q19: How many AC Current Sensors can I connect in one VE.Bus system?
- 15.20. Q20: Issues with Multi not starting when Cerbo GX is connected / Caution when powering the Cerbo GX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro
- 15.21. Q21: I love Linux, programming, Victron and the Cerbo GX. Can I do more?
- 15.22. Q22: How do I change the logo
- 15.23. Q23: Multi restarts all the time (after every 10sec)
- 15.24. Q24: What is Error #42?
- 15.25. GPL Note
- 16. More information
Quiet hours
Quiet hours allows you to define a period during which the noise from a running generator would be a nuisance; and to set
different values to the conditions which would cause an auto-start during this period - thus ensuring that the generator will only
start during a quiet period when it is absolutely necessary.
From the main menu go to: Settings → Generator start/stop → Settings; and then toggle-on the Quiet hours feature. Define
the Quiet hours start- and end- times in the boxes which appear below.
Quiet hours will become the permanent condition (when enabled) if the defined 'start' and 'stop' times are the same.
Using "Quiet hours" as a tool to define two sets of user-preferences
Alternatively, the “Quiet hours” feature can be used to define how you wish your system to respond to different circumstances - for
example:
• Early morning/low SOC: Battery SOC is often lowest in the morning. Couple this with cloudy weather first thing - or panels
which have a westerly bias, and which tend to do better in the afternoon; and you have a circumstance where the generator
may auto-start in the morning triggered by a low battery SOC condition - yet later on when the day brightens the solar energy is
wasted because the work has already been done by the generator. Setting the Quiet hours feature to cover this period, together
with lower auto-start conditions, will help to avoid unnecessary generator auto-starts.
• Holiday home: Holiday homes which are only inhabited part-time experience much deeper power-draws when they are in use.
The Quiet hours feature can be used to set much lower auto-start parameters when the house is in use, than when it is empty.
Quiet hours should be set to be the permanent condition (See above) during occupation; and the Quiet hours feature can be
toggled 'off' whenever the house is empty.
13.7. Troubleshooting
Fischer Panda: Generator does not start and "Remote switch control disabled" error is show
Enable the “AutoStart” function in the Fischer Panda control panel.
Fischer Panda: Auto start/stop function has stopped working after an error
Make sure that the issue is solved, then clear the error, and the auto start/stop function will work again.
Cerbo GX Manual
Page 68 GX - Generator auto start/stop