Configuration of the sensor
Normally, the Sensor should work out of the box. In case it does not, for example when the sensor has previously been used in
another system, then:
1. Download the Si-MODBUS-Configuration software tool from the IMT website.
2. Configure the following settings: Modbus Address - 3, Baud Rate: 9600, Data Format: 8N1 (10 Bit): which are all the default
settings as when shipped by IMT.
For more support on configuring the IMT sensor, please contact IMT.
Connecting only an IMT temperature sensor
Both RS485-MB single temperature sensors of IMT are compatible too.
The Tm-RS485-MB will be visible as the 'Cell temperature'.
The Ta-ext-RS485-MB will be visible as the 'External or ambient temperature'
Connecting multiple IMT sensors
It's possible to connect multiple IMT sensors. A separate USB to RS485 converter cable is required for each sensor.
You can't combine multiple Si-Sensor RS485 sensors on one bus, our software supports only one. To use multiple sensors, you
will also need to add multiple USB to RS485 converters.