LSP Data Sheet
www.victronenergy.com
Integrated BMS and safety switch
The SuperPack batteries are extremely easy to install, needing no additional components.
The internal switch will disconnect the battery in case of over discharge, over charge, low or high temperature.
Abuse proof
A lead-acid battery will fail prematurely due to sulfation:
• If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all, fully charged).
• If it is left partially charged or worse, fully discharged.
A Lithium-Ion battery does not need to be fully charged. Service life even slightly improves in case of partial charge instead of a full charge. This
is a major advantage of Li-ion compared to lead-acid.
The SuperPack batteries will cut-off the charge or discharge current when the maximum ratings are exceeded.
Efficient
In several applications (especially off-grid solar), energy efficiency can be of crucial importance.
The round-trip energy efficiency (discharge from 100 % to 0 % and back to 100 % charged) of the average lead-acid battery is 80 % .
The round-trip energy efficiency of a Li-ion battery is 92 % .
The charge process of lead-acid batteries becomes particularly inefficient when the 80 % state of charge has been reached, resulting in
efficiencies of 50 % or even less in solar systems where several days of reserve energy are required (battery operating in 70 % to 100 % charged
state).
In contrast, a Li-ion battery will still achieve 90 % efficiency even under shallow discharge conditions.
Can be connected in parallel
The batteries can be connected in parallel. Series connection is not allowed.
Use in upright position only.
12,8 V & 25,6 V Lithium SuperPack batteries
Lithium SuperPack
12,8/20 12,8/60 12,8/100
12,8/100
High
current
12,8/200 25,6/50
Chemistry LiFePO4
Nominal voltage 12,8 V 25,6 V
Nominal capacity @ 25 °C 20 Ah 60 Ah 100 Ah 200 Ah 50 Ah
Nominal capacity @ 0 °C 16 Ah 48 Ah 80 Ah 160 Ah 40 Ah
Nominal energy @ 25 °C
256 Wh 768 Wh 1280 Wh 2560 Wh 1280 Wh
Cycle life @ 80 % DoD and 25 °C
2500 cycles
CHARGE and DISCHARGE
Max. cont. discharge current
(1)
30 A 30 A 50 A 100 A 70 A 50 A
Peak discharge current (10 sec) 80 A 80 A 100 A 150 A 100 A 100 A
End of discharge voltage 10 V 20 V
Charge voltage, absorption
(2)
14,2 V – 14,4 V
28,4 V –
28,8 V
Charge voltage, float 13,5 V 27 V
Max. cont. charge current 15 A 30 A 50 A 100 A 70 A 50 A
OPERATING CONDITIONS
Parallel configuration Yes, unlimited
Series configuration No
Operating temperature Discharge: -20 °C to +50 °C Charge: +0 °C to +45 °C
(3)
Storage temperature -40 °C to +65 °C
Max. storage time when fully
charged
1 year ≤ 25 °C 3 months ≤ 40 °C
Humidity (non-condensing) Max. 95 %
Protection class IP 43
OTHER
Power connection (threaded
inserts)
M5 M6 M8 M8 M8
Dimensions (h x w x d) mm
167 x 181
x 77
213 x 229
x 138
220 x 330
x 172
208 x 520
x 269
220 x 330
x 172
Weight 3,5 kg 9,5 kg 14 kg 21 kg 14 kg
1. The battery may disconnect when a load with a high input capacitance is connected, such as an inverter. The battery will however retry and
connect after approximately 10 seconds.
2. The absorption period should preferably not exceed 4 hrs. A longer absorption period may slightly reduce service life.
3. Serial number HQ2040 and newer: charge is automatically blocked when the cell temperature decreases below 0±3 °C. It will accept
charging again when increased above 3±3 °C. Discharge is automatically blocked when cell temperature decreases below -20±3 °C. This
protection resets when temperature above -15±3 °C.