Phoenix Inverter VE.Direct 250VA - 1200VA

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Phoenix Inverter
24 Volt
12/250
24/250
48/250
12/375
24/375
48/375
12/500
24/500
48/500
12/800
24/800
48/800
12/1200
24/1200
48/1200
Cont. power at 25°C (1) 250VA 375VA 500VA 800VA 1200VA
Cont. power at 25°C / 40°C 200 / 175W 300 / 260W 400 / 350W 650 / 560W 1000 / 850W
Peak power 400W 700W 900W 1500W 2200W
Output AC voltage / frequency (adjustable) 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
DC low shut down (adjustable) 9,3 / 18,6 / 37,2V
Dynamic (load dependent) DC low shut down
(fully configurable)
Dynamic cut-off, see
https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
DC low restart and alarm (adjustable) 10,9 / 21,8 / 43,6V
Battery charged detect (adjustable) 14,0 / 28,0 / 56,0V
Max. efficiency 87 / 88 / 88% 89 / 89 / 90% 90 / 90 / 91% 90 / 90 / 91% 91 / 91 / 92%
Zero-load power 4,2 / 5,2 / 7,9W 5,6 / 6,1 / 8,5W 6 / 6,5 / 9W 6,5 / 7 / 9,5W 7 / 8 / 10W
Default zero-load power in ECO mode
(default retry interval: 2,5 s, adjustable)
0,8 / 1,3 / 2,5W 0,9 / 1,4 / 2,6W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W
ECO mode stop and start power setting Adjustable
Protection (2) a - f
Operating temperature range -40 to +65°C (fan assisted cooling) Derate 1,25% per °C above 40°C
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour Steel chassis and plastic cover (blue Ral 5012)
Battery-connection Screw terminals
Maximum cable cross-section 10mm² / AWG8 10mm² / AWG8 10mm² / AWG8
25 / 10 / 10mm² /
AWG4 / 8 / 8
35 / 25 / 25mm
2
/
AWG2 / 4 / 4
Standard AC outlets
230V: Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
120V: Nema 5-15R, GFCI
Protection category IP 21
Weight 2,4kg / 5,3lbs 3,0kg / 6,6lbs 3,9kg / 8.5lbs 5,5kg / 12lbs 7,4kg / 16,3lbs
Dimensions (h x w x d, mm)
(h x w x d, inch)
86 x 165 x 260
3.4 x 6.5 x 10.2
86 x 165 x 260
3.4 x 6.5 x 10.2
86 x 172 x 275
3,4 x 6,8 x 10,8
105 x 216 x 305
4.1 x 8.5 x 12.1
(12V model:
105 x 230 x 325)
117 x 232 x 327
4.6 x 9.1 x 12.9
(12V model:
117 x 232 x 362)
ACCESSORIES
Remote on-off Yes
Automatic transfer switch Filax
STANDARDS
Safety EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)
EMC EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
Automotive Directive ECE R10-4
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
3) UL 458 only for inverters with GFCI output socket
Battery Alarm
An excessively high or low battery voltage is indicated
by an audible and visual alarm, and a relay for remote
signalling.
BMV Battery Monitor
The BMV Battery Monitor features an advanced microprocessor control system combined
with high resolution measuring systems for battery voltage and charge/discharge current.
Besides this, the software includes complex calculation algorithms to exactly determine
the state of charge of the battery. The BMV selectively displays battery voltage, current,
consumed Ah or time to go. The monitor also stores a host of data regarding performance
and use of the battery.
VE.Direct Bluetooth Smart dongle
(must be ordered separately)