8. Technical specifications
Quattro 12/5000/200 24/5000/120 48/5000/70
PowerControl / PowerAssist Yes Yes Yes
Integrated Transfer switch Yes Yes Yes
AC inputs (2x)
Input voltage range: 187-265 VAC Input frequency: 45 – 55 Hz Power factor: 1
Maximum feed through current (A)
30 30 30
INVERTER
Input voltage range (V DC) 9,5 – 17 19 – 33 38 – 66
Output
(1)
Output voltage: 230 VAC ± 2% Frequency
:
50 Hz ± 0,1%
Cont. output power at 25 °C (VA)
(3)
5000 5000 5000
Cont. output power at 25 °C (W) 4000 4250 4250
Cont. output power at 40 °C (W) 3000 3350 3350
Peak power (W) 7000 7500 7800
Maximum efficiency (%) 92 94 95
Zero-load power (W) 25 30 30
Load shedding output Maximum load: 10A Switches off when no external AC source available
CHARGER
Charge voltage 'absorption' (V DC) 14,4 28,8 57,6
Charge voltage 'float' (V DC) 13,8 27,6 55,2
Storage mode (V DC) 13,2 26,4 52,8
Charge current house battery (A)
(4)
200 120 70
Charge current starter battery (A) 4
Battery temperature sensor ja
GENERAL
Multi purpose relay
(5)
Yes
Yes
Yes
Protection
(2)
a - g
Common Characteristics Operating temp.: -20 to +50°C (fan assisted cooling) Humidity (non condensing) : max 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection Four M8 bolts (2 plus and 2 minus connctions)
230 V AC-connection Screw clamp 13mm² (AWG 6)
Weight (kg) 30
Dimensions (hxwxd in mm) 444 x 328 x 240
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission / Immunity EN55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3
Automotive Directive 2004/104/EC
1) Can be adjusted to 60 Hz; 120 V 60 Hz on request
2)
Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
f. 230VAC on inverter output
g. Input voltage ripple too high
h. Temperature too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Multipurpose relay which can be set for general