Canbus PGN overview per product
Use below tables to see where to find what data. There is a freely available PDF file on the NMEA2000 website that also gives a good overview. Go to
http://www.nmea.org/content/nmea_standards/downloads.asp, and then the link called “NMEA2000 Parameter Group Descriptions (Messages) with
Field Description”. To get the detailed information in order to decode the PGNs, see Q14 in the FAQs.
VE.Bus products (Multi’s, Quattro and Inverters)
Data
PGN Name
PGN dec
PGN hex
Field
Remarks
Battery voltage
Battery Status
127508
0x1F214
2
Battery current
Battery Status
127508
0x1F214
3
State of Charge (%)
DC Detailed Status
127506
0x1F212
4
This PGN is disabled by default, since the reported value is
only valid in systems with no other chargers or dc loads. Use
the proper NMEA method to enable it, which is a complex
request.
Battery temperature
Battery Status
127508
0x1F214
4
Charger on/off switch
Charger Status
127507
0x1F213
5
Charge state
Charger Status
127507
0x1F213
3
Off, bulk, absorption, float etcetera.
Inverter on/off switch
Inverter Status
127509
0x1F215
5
Inverter Operating
State
Inverter Status
127509
0x1F215
4
Off, inverting, etcetera.
L1 AC input voltage
J1939-75 PGN
65014
0xFDF6
AC input information is sent from a different network address
than all other PGNs. To distinguish, use the device function
code from the ACL PGN, which is “154 AC Input monitor” for
the AC input information. All other PGN’s are sent with device
function code “153 Inverter”. See manual for more
information.
L1 AC input current
J1939-75 PGN
65014
0xFDF6
L1 AC input frequency
J1939-75 PGN
65014
0xFDF6
L1 AC input power
J1939-75 PGN
65013
0xFDF5
L1 AC output voltage
J1939-75 PGN
65014
0xFDF6
These parameters are sent per phase, see manual for
information about all phases.
L1 AC output current
J1939-75 PGN
65014
0xFDF6
L1 AC output
frequency
J1939-75 PGN
65014
0xFDF6
L1 AC output power
J1939-75 PGN
65013
0xFDF5
Warnings and alarms
Binary Switch Bank Status
127501
0x1F20D
Switch bank instance 0
LED states
Binary Switch Bank Status
127501
0x1F20D
Switch bank instance 1. This message is by default not
enabled, see manual on how to enable it.
The Battery instance from PGNs 127508 (field 1), DC Instance from PGN 127506 (field 2) and PGN 127509 (field 3) and Charger Instance from PGN 127507
(field 1) are the same number. Changing one of the instances will change all of the mentioned instances.
See the VE.Bus to NMEA2000 interface manual for more details (https://www.victronenergy.com/accessories/ve-bus-to-nmea2000-interface).
Skylla-i/-IP44 battery charger family
Data
PGN Name
PGN dec
PGN hex
Field
Remarks
Battery voltage
Battery Status
127508
0x1F214
2
The 3-output model has 3 instances of PGN 0x1F214, one for each output.
Field 1 of this PGN, Battery Instance is used to distinguish between them.
Battery current
Battery Status
127508
0x1F214
3
Battery temperature
Battery Status
127508
0x1F214
4
Relay and alarms
Binary Switch
Bank Status
127501
0x1F20D
Charger state
Converter
Status
127750
0x1F306
3
Off, bulk, absorption, float etcetera.
AC input current
AC Power /
Current Phase
127744
0x1F300
3
AC RMS Current
Charger on/off
Charger Status
127507
0x1F213
5
DEPRECATED: PGNs 127507 and 127503 are deprecated in favor of
127750 and 127744
They are not being transmitted by default. They can still be requested
though, and also they can be configured to be transmitted on an interval.
Charge state
Charger Status
127507
0x1F213
3
AC input current
9
AC Input Status
127503
0x1F20F
7
Equalization pending
Charger Status
127507
0x1F213
6
Equal. time
remaining
Charger Status
127507
0x1F213
8
Note that the Skylla-i/-IP44 will switch off when there is no mains available. It will therefore also stop sending and responding to Canbus messages.
9
The AC Input Status PGN 127503 is not present on the Skylla-IP44