Feature highlights common to all models
Ultra-fast Maximum Power Point Tracking (MPPT).
Advanced Maximum Power Point Detection in case of partial shading conditions.
Outstanding conversion efficiency.
Natural convection cooling.
Automatic battery voltage recognition.
Flexible charge algorithm.
Over temperature protection and power derating when temperature is high.
Sizing options:
Suitable for a variety of battery voltages. Most models connect to 12, 24, and 48V batteries, some only
connect to 12 and 24V batteries, or only to 48V batteries.
Charge currents rating from 10A all the way up to 100A.
Maximum PV array Voc voltages ranging from 75V up to 250V.
Multiple chargers can be used in parallel, for large systems we recommend to use the models with a
VE.Can communication port.
PV terminal options:
TR - one positive and one negative screw terminal.
MC4 - 3 pairs of paralleled MC4 connectors.
Bluetooth options:
SmartSolar models have Bluetooth.
BlueSolar models do not have Bluetooth. They can be retrofitted to have Bluetooth by connecting the
VE.Direct Bluetooth Smart dongle. Advantage: the product is not Bluetooth accessible when the
dongle is not connected. Note that on the SmartSolar models, Bluetooth can be disabled.
Display options:
VictronConnect Application. Connects via Bluetooth or via the VE.Direct - USB interface
MPPT Control. Connects to all models via a VE.Direct cable
SmartSolar Control Display. Plugs directly into the housing of the larger models
GX device
VRM website (GX monitoring device needed)
Communication ports:
VE.Direct - all models
VE.Direct and VE.Can - limited models. VE.Can is especially suitable for systems with multiple solar
chargers. All units are simply “daisy chained” to each other with a single RJ45 cable between each unit
and also between the las unit in the chain and the a GX monitoring device.
Temperature sensor options:
Internally (all models).
Externally via the Smart Battery Sense (only SmartSolar models).
Load output options:
Physical output - On the 10, 15 and 20A models.
Virtual output - via VE.Direct TX digital output cable and the BatteryProtect or a solid-state relay.
Remotely enabling and disabling the charger:
All larger units feature the Victron standard remote on/off terminals. All models that don’t feature an
onboard Remote on/off terminal can be remotely controlled by using the VE.Direct non inverting
remote on/off cable ASS030550310. Note that this prohibits using the VE.Direct port for anything
else.
Firmware update options:
Local updates via the VictronConnect Application (via Bluetooth or USB-VE.Direct interface)
Remote updates via VRM website and a GX device
Optional accessories:
VictronConnect Application (free download)
Wire boxes, to cover and protect the terminals. See table on page 2 for wire box types
Control and display panels: MPPT control or SmartSolar control)
GX monitoring device (CCGX, Venus GX, Octo GX or Cerbo GX)
Data cables: VE.Direct cable, RJ45 Cable (VE.Can models only), USB-VE.Direct interface
External control cables: TX cable, non-inverting cable
Bluetooth dongle (for non-smart models)
More information:
To access the above-mentioned documents or information: press the search button on our website
and enter the appropriate search word.
For connection to a Color Control GX or other GX device see:
https://www.victronenergy.com/live/venus-os:start.
BlueSolar and SmartSolar MPPT Charge Controllers
Overview
Maximum Power Point Tracking
(MPPT)
Upper curve:
Output current (I) of a solar panel as
function of output voltage (V).
The Maximum Power Point (MPP) is the
point Pmax along the curve where the
product I x V reaches its peak.
Lower curve:
Output power P = I x V as function of
output voltage.
When using a PWM (not MPPT)
controller the output voltage of the
solar panel will be nearly equal to the
voltage of the battery, and will be lower
than Vmp.
MPPT Control
SmartSolar Control
VictronConnect
Application