Victron BMS overview

E-mail: sales@victronenergy.com |
Features Small BMS VE.Bus BMS V2 VE.Bus BMS Lynx Smart BMS
Smart BMS CL
12/100
Smart BMS 12/200 BMS 12/200
System voltage
12, 24 or 48 V 12, 24 or 48 V 12, 24 or 48 V 12, 24 or 48 V 12 V 12 V 12 V
System connection
No No No 500 A No 200 A 200 A
Alternator port
No No No
Yes (Alternator
ATC mode)
100 A 100 A 80 A
Battery monitor
No No No Yes No No No
Bluetooth
No No No Yes Yes Yes No
Data communication
No
VE.Bus
communication
with
inverter/charger(s)
and a GX device.
VE.Bus
communication
only direct with
inverter/charger(s),
not with a GX
device.
VE.Can
communication
with a GX device
NMEA 2000
No No No
Control via GX device
(DVCC)
No Yes No Yes No No No
Allowed to discharge
terminal(s)
High/free floating
1 A
High/free floating
1 A
High/free floating
2 A
Relay
0.5 A
High/free floating
10 mA
High/free floating
10 mA
No
Allowed to charge
terminal(s)
High/free floating
10 mA
High/free floating
10 mA
High/free floating
10 mA
Relay
0.5 A
High/free floating
10 mA
High/free floating
10 mA
No
Pre-alarm terminal(s)
Free floating/high
1 A
Free floating/high
1 A
Free floating/high
1 A
Programmable
relay
2 A
Free floating/high
1 A
Free floating/high
1 A
No
Remote on/off
terminal
Yes Yes No Yes Yes Yes Yes
Auxiliary output
No Yes, 1 A No Yes, 1.1 A No No No
Auxiliary input
No Yes, 1 A No No No No No
Possible to update
firmware
No No No Yes Yes Yes No
Weight (kg)
0.1 0.12 0.1 1.9 1.6 2.0 1.8
Dimensions (mm)
106 x 42 x 23 24 x 95 x 106 105 x 78 x 32 190 x 180 x 80 65 x 120 x 224 65 x 120 x 340 mm 65 x 120 x 260
Protection
IP20 IP20 IP20 IP22 IP65 IP65 IP65
Remarks
- -
End-of-life, use a
VE.Bus BMS V2
instead
Is part of the Lynx
Distribution
System
A future 1000 A
model will replace
this model
- -
End-of-life, use a
Smart BMS 12/200
instead
Datasheet
smallBMS with pre
alarm
VE.Bus BMS V2 VE.Bus BMS Lynx Smart BMS
Smart BMS CL
12/100
Smart BMS 12/200 BMS 12/200
Lithium Battery 12,8V
& 25,6V Smart
M8 circular connector 3
pole cable
Cable for Smart BMS
CL 12/100 to
MultiPlus
Inverting remote on-
off cable
VE.Direct non
inverting remote
on/off cable
Non inverting remote
on-off cable
Comparison overview:
The below overview is a comparison and a brief summary of the BMS features. For full technical specifications, see the individual BMS datasheets.