Product Manual

21
NL FR DE ES SE IT PT
EN NL FR DE ES SE IT PT
4 FULL SETUP DETAILS
4.1 Using the menus
(alternatively, use the VictronConnect app and smart phone)
Four buttons control the BMV. The function of the buttons depends on
which mode the BMV is in.
Button
Function
When in normal mode
When in setup mode
If backlight is off, press any button to restore backlight
SETUP
Press and hold for two seconds
to switch to setup mode.
The display will scroll the number
and description of the selected
parameter.
Press SETUP at any time to return to the
scrolling text, and press again to return to
normal mode.
When pressing SETUP while a parameter
is out of range, the display blinks 5 times
and the nearest valid value is displayed.
SELECT
Press to switch to history menu.
Press to stop scrolling and show
the value. Press again to switch
back to normal mode.
- Press to stop scrolling after entering the
setup mode with the SETUP button.
- After editing the last digit, press to end
editing. The value is stored automatically.
Confirmation is indicated by a short beep.
- If required, press again to restart editing.
SETUP/
SELECT
Press and hold both SETUP and
SELECT buttons simultaneously
for three seconds to restore
factory settings (disabled when
setting 64, lock setup, is on, see
section 4.2.5)
+ Move upwards
When not editing, press to move up to the
previous parameter.
When editing, this button will increment
the value of the selected digit.
Move downwards
When not editing, press to move down to
the next parameter.
When editing, this button will decrement
the value of the selected digit.
BMV-712 only: Press and hold
for three seconds (until the
confirmation beep) to start
automatic cycling through status
items.
+/
Press and hold both buttons
simultaneously for three seconds
to manually synchronize the BMV