Product Manual

22
When power is applied for the first time or when factory settings have
been restored, the BMV will start the quick setup wizard: see section 1.
Thereafter, if power is applied, the BMV will start in normal mode: see
section 2.
4.2 Functions overview
The following summary describes all the parameters of the BMV.
- Press SETUP for two seconds to access these functions and use the
+ and buttons to browse them.
- Press SELECT to access the desired parameter.
- Use SELECT and the + and buttons to customize. A short beep
confirms the setting.
- Press SETUP at any time to return to the scrolling text, and press
again to return to normal mode.
4.2.1 Battery settings
______________________________________________________________
01. Battery capacity
Battery capacity in amp hours
Default Range Step size
200Ah 1 – 9999Ah 1Ah
______________________________________________________________
02. Charged Voltage
The battery voltage must be above this voltage level to consider the battery as fully
charged.
The charged-voltage-parameter should always be slightly below the end of charge voltage of the
charger (usually 0.2V or 0.3V below the ‘float’ voltage of the charger).
See section 3.7 for recommended settings.
BMV-700 / BMV-702 / BMV-712 Smart
Default Range Step size
See table, sect 3.7 0 95V 0,1V
BMV-700H
Default Range Step size
158,4V 0 384V 0,1V
______________________________________________________________
03. Tail current
Once the charge current has dropped to less than the set tail current (expressed as
percentage of the battery capacity), the battery is considered as fully charged.
Remark:
Some battery chargers stop charging when the current drops below a set threshold. The tail current must
be set higher than this threshold.
Default Range Step size
4% 0,5 10% 0,1%