57. Time-to-go display
Must be ON to display time-to-go in the monitoring menu.
58 Starter voltage display - 702 and -712 only
Must be ON to display the auxiliary voltage in the monitoring menu.
59. Temperature display - 702 and -712 only
Must be ON to display the temperature in the monitoring menu.
60. Mid-voltage display - 702 and -712 only
Must be ON to display the mid-point voltage in the monitoring menu.
Default Range
ON ON/OFF
4.2.5 Miscellaneous
______________________________________________________________
61. Software version (read only)
The software version of the BMV
62. Restore defaults
Resets all settings to factory default by pressing SELECT.
When in normal operating mode, factory settings can be restored by pressing SETUP and SELECT
simultaneously for 3 seconds (only if setting 64, Lock setup, is off).
63. Clear history
Clears all history data by pressing SELECT.
_______________________________________________________________
64. Lock setup
When on, all settings (except this one) are locked and cannot be altered.
Default Range
OFF OFF/ON
_______________________________________________________________
65. Shunt current
When using a shunt other than the one supplied with the BMV, set to the rated current of the
shunt.
Default Range Step size
500A 1 9999A 1A
_______________________________________________________________
66. Shunt voltage
When using a shunt other than the one supplied with the BMV, set to the rated voltage of the
shunt.
Default Range Step size
50mV 1mV75mV 1mV