4. Installation
4.1. General
Mount vertically on a non-flammable surface, with the power terminals facing downwards. Observe a minimum clearance of 10
cm under and above the product for optimal cooling.
Mount close to the battery, but never directly above the battery (in order to prevent damage due to gassing of the battery).
4.2. Connection setup for DC-DC converter mode
1. Disconnect the remote on/off (remove wire bridge).
2. Connect the input supply cables.
3. Open the VictronConnect App to setup the product. (always adjust the output voltage before connecting in parallel or
connecting a battery)
4. Connect the load. The converter is now ready for use.
5. Reconnect the remote on/off to activate the product.
Figure 1: Typical connection setup as DC-DC converter
4.3. Connection setup for charger mode
1. Disconnect the remote on/off (remove wire bridge).
2. Connect the input supply cables.
3. Open the VictronConnect App to setup the product. (always setup the correct charger algorithm before connecting a
battery)
4. Connect the battery to be charged.
5. Reconnect the remote on/off to activate the product.
Orion-Tr Smart DC-DC Charger Non-Isolated
Page 4 Installation