4.2. Temperature compensation
The Victron blue smart charger range will automatically compensate the configured charge voltage based on ambient
temperature (except for Li-ion mode or if manually disabled).
The optimal charge voltage of a lead acid battery varies inversely with battery temperature; automatic temperature-based charge
voltage compensation avoids the need for special charge voltage settings in hot or cold environments.
During power up the charger will measure its internal temperature and use that temperature as the reference for temperature
compensation, however the initial temperature measurement is limited to 25°C as it’s unknown if the charger is still warm from
earlier operation.
Since the charger generates some heat during operation, the internal temperature measurement is only used dynamically if the
internal temperature measurement is considered reliable; when the charge current has decreased to a low/negligible level and
adequate time has elapsed for the chargers temperature to stabilise.
The configured charge voltage is related to a nominal temperature of 25°C and linear temperature compensation occurs between
the limits of 6°C and 50°C based on the default temperature compensation coefficient of 16.2mV/°C (for 24v chargers multiply the
coefficient by 2) or as configured.
The temperature compensation coefficient is specified in mV/°C and applies to the entire battery/battery bank (not per battery
cell).
Blue Smart IP22 Charger
Page 6 Operation