SoC cycle end
The state of charge cycle end setting is used to ......
This setting is fixed at 90%.
SoC cycle
The state of charge cycle setting is used to ......
This setting is fixed at 65%.
SoC full discharge
The state of charge full discharge setting is used to ......
This setting is fixed at 5%.
6.3.5. Settings Lynx Distributor
These instructions only apply if the system contains one or more Lynx Distributors.
Each Lynx distributor must be addressed and set to A, B, C or D. This is done via a 2-way dip switch located inside the Lynx
distributor. Refer to chapter 6.1.3. Addressing Lynx Distributor in the Lynx distributor manual.
Use the VictronConnect App to give each fuse a custom name (maximum 16 characters). If the fuse name is empty (0
characters), the fuse will be disabled from monitoring and be ignored.
Navigate to the settings page by clicking the gear symbol at the top right-hand corner.
On the settings page scroll down to the Lynx Distributor settings.
Click on a fuse name and a window opens to rename the fuse.
Setting the Lynx Distributor fuse names using VictronConnect
Lynx Smart BMS