Product Manual

18
Specifications - continuation
Orion-Tr Smart Charger
Isolated 360 400 Watt
24/12-30
(360W)
24/24-17
(400W)
Input voltage range (1)
20-35V
20-35V
Under voltage shut down
14V
14V
Under voltage restart
15V
15V
Nominal output voltage
12,2V
24,2V
Output voltage adjust range
10-15V
20-30V
Output voltage tolerance
+/- 0,2V
Output noise
2mV rms
Cont. output current at nominal
output voltage and 40°C
30A 17A
Maximum output current (10 s)
at nominal output voltage
45A 25A
Short circuit output current
60A
40A
Cont. output power at 25°C
430W
480W
Cont. output power at 40°C
360W
400W
Efficiency
88%
89%
No load input current
< 100mA
< 80mA
Standby current
Less than 1mA
Galvanic isolation
200V dc between input, output and case
Operating temperature range
-20 to +55°C (derate 3% per °C above 40°C)
Humidity
Max. 95% non-condensing
DC connection
Screw terminals
Maximum cable cross-section
16mm² AWG6
Weight
12V input and/or 12V output models: 1,8 kg (3 lb)
Other models: 1,6 kg (3.5 lb)
Dimensions hxwxd
12V input and/or 12V output models:
130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)
Other models: 130 x 186 x 70 mm
(5.1 x 7.3 x 2.8 inch)
Standards: Safety
Emission
Immunity
Automotive Directive
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
ECE R10-5
1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified
input voltage range (buck-boost function).
If the output voltage is set higher than nominal by a certain percentage, the minimum input
voltage at which the output voltage remains stable (does not decrease) increases by the same
percentage.
Note 1) The VictronConnect App will not display current in or current out.
Note 2) The Orion-Tr Smart is not equipped with a VE.Direct port.