Product Manual

7
victron energy
Adjustments without remote panel
WARNING: Always check with your battery
supplier if the choosen charge characteristic is
suitable for your battery and application
Remove the frontplate and disconnect battery
and Voltage sense and Temperature sense and
connect a digital voltmeter to – and +1 output.
Bulk-current
While switching on keep both the pushbuttons
& pushed.
Release pushbuttons.
Bulk LED is flashing alternately with Failure LED.
Push for up and for down.
Reading as follows:
Discard first digit of DVM then multiply by 10, i.e:
22.50V => ….2.50 => 25 Amps
15.00V => .....5.00 => 50 Amps
Switch the charger Off to store.
Absorption and Float voltage
While switching on keep the pushbutton
pushed for Absorption voltage and for Float-
voltage.
Release pushbuttons.
Absorption or Float LED is flashing alternately
with Failure LED.
Push for up and for down.
Reading on voltmeter as is.
Switch the charger Off to store.
Please note that in adjust-mode the
Temperature sense compensation is not taken
into account.
Warning: If the charger is not switched Off
after an adjustment the new value will not be
stored but will remain on the outputs. After 4
hours the charger continues the normal
sequence with the old values. This can be
useful if a forced high voltage is wanted to get
some life in an assumed ‘dead’ battery.
Return to factory settings
Switch the charger on.
Keep the pushbutton and/ or pushed while
switching off.
The factory settings are restored.
When ready
Connect battery and if applicable Voltage sense
and Temperature sense.
Replace the frontplate.
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Adjusting maximum Bulk current
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Adjusting Float voltage
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Adjusting Absorption voltage
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Restoring defaults