Product Card

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Phoenix Inverter Smart
12/1600
24/1600
48/1600
24/2000
12/3000
24/3000
48/3000
Parallel and 3-phase operation No
INVERTER
Input voltage range (1) 9,3 – 17V 18,6 34V 37,2 68V
Output Output voltage: 230VAC ±2% 50 Hz or 60Hz ± 0,1% (1)
Cont. output power at 25
º
C (2) 1600VA 2000VA 3000VA
Cont. output power at 25ºC 1300W 1600W 2400W
Cont. output power at 40ºC 1200W 1450W 2200W
Cont. output power at 65ºC 800W 1000W 1700W
Peak power 3000VA 4000VA 6000VA
Dynamic (load dependent) DC low shut
down (fully configurable)
Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
Max. efficiency 12/ 24 /48 V 92 / 94 / 94% 92 / 94 / 94% 93 / 94 / 95%
Zero load power 12 / 24 / 48 V 8 / 9 / 11W 8 / 9 / 11W 12 / 13 / 15W
Zero load power in ECO mode 0,6 / 1,3 / 2,1W 0,6 / 1,3 / 2,1W 1,5 / 1,9 / 2,8W
GENERAL
Programmable relay (2) Yes
Stop & start power ECO-mode adjustable
Protection (3) a - g
Bluetooth wireless communication For remote monitoring and system integration
VE.Direct communication port For remote monitoring and system integration
Remote on-off Yes
Common Characteristics
Operating temperature range: -40 to +65ºC (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: steel (blue RAL 5012; and black RAL 9017) Protection category: IP 21
Battery-connection M8 bolts M8 bolts 2+2 M8 bolts
230 V AC-connection Screw terminals
Weight 12kg 13kg 19kg
Dimensions (hxwxd) 485x219x125mm 485x219x125mm
533x285x150mm (12V)
485x285x150mm (24V/48V)
STANDARDS
Safety EN 60335-1
Emission Immunity EN 55014-1 / EN 55014-2/ EN-IEC 61000-6-1 / EN-IEC 61000-6-2 / EN-IEC 61000-6-3
Automotive Directive ECE R10-5
1) Non-linear load, crest factor 3:1
2) Programmable relay that can a.o. be set
for general alarm, DC under voltage or
genset
start/stop function.
AC rating: 230 V / 4 A
DC rating: 4 A / 35 VDC, 1A / 60VDC
3) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high
Phoenix Inverter Control
This panel is intended for remote
on/off control of all Phoenix
inverters Smart
Color Control GX and other GX devices
Provides monitoring and control.
Locally, and remotely on the VRM Portal.
BMV-712 Smart Battery
Monitor
The BMV Battery Monitor features an
advanced microprocessor control
system combined with high
resolution measuring systems for
battery voltage and
charge/discharge current. Besides
this, the software includes complex
calculation algorithms, like Peukert’s
formula, to exactly determine the
state of charge of the battery. The
BMV selectively displays battery
voltage, current, consumed Ah or
time to go. The monitor also stores a
host of data regarding performance
and use of the battery.
VE.Direct to USB interface
Connects to a USB port.
Bluetooth wireless communication
Connects to a smart phone (both iOS and
Android).