Brochure

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com |
www.victronenergy.com
Phoenix Inverter
C12/1200
C24/1200
C12/1600
C24/1600
C12/2000
C24/2000
12/3000
24/3000
48/3000
24/5000
Parallel and 3-phase operation Yes
INVERTER
Input voltage range (V DC) 9,5 17V 19 33V 38 66V
Output Output voltage: 230 VAC ±2% Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25
º
C (VA) (2) 1200 1600 2000 3000 5000
Cont. output power at 25
º
C (W) 1000 1300 1600 2400 4000
Cont. output power at 40ºC (W) 900 1200 1450 2200 3700
Cont. output power at 65ºC (W) 600 800 1000 1700 3000
Peak power (W) 2400 3000 4000 6000 10000
Max. efficiency 12/ 24 /48 V (%) 92 / 94 / 94 92 / 94 / 94 92 / 92 93 / 94 / 95 94 / 95
Zero load power 12 / 24 / 48 V (W) 8 / 10 / 12 8 / 10 / 12 9 / 11 20 / 20 / 25 30 / 35
Zero load power in AES mode (W) 5 / 8 / 10 5 / 8 / 10 7 / 9 15 / 15 / 20 25 / 30
Zero load power in Search mode (W) 2 / 3 / 4 2 / 3 / 4 3 / 4 8 / 10 / 12 10 / 15
GENERAL
Programmable relay (3) Yes
Protection (4) a - g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
Remote on-off Yes
Common Characteristics
Operating temperature range: -40 to +65ºC (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection battery cables of 1.5 meter included M8 bolts 2+2 M8 bolts
230 V AC-connection G-ST18i plug Spring-clamp Screw terminals
Weight (kg) 10 12 18 30
Dimensions (hxwhd in mm) 375x214x110 520x255x125 362x258x218 444x328x240
STANDARDS
Safety EN 60335-1
Emission Immunity EN 55014-1 / EN 55014-2
1) Can be adjusted to 60 Hz and to 240 V
2) Non-linear load, crest factor 3:1
3) Programmable relay that can a.o. be set for
general alarm, DC under voltage or genset
start/stop function.
AC rating: 230 V / 4 A
DC rating: 4 A up to 35 VDC, 1A up to
60VDC
4) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high
Computer controlled operation and monitoring
Several interfaces are available:
Phoenix Inverter Control
This panel can also be used on a
MultiPlus Inverter/Charger when an
automatic transfer switch but no
charger function is desired.
The brightness of the LEDs is
automatically reduced during night
time.
BMV-700 Battery Monitor
The BMV-700 Battery Monitor features an
advanced microprocessor control system
combined with high resolution
measuring systems for battery voltage
and charge/discharge current. Besides
this, the software includes complex
calculation algorithms, like Peukert’s
formula, to exactly determine the state of
charge of the battery. The BMV-700
selectively displays battery voltage,
current, consumed Ah or time to go. The
monitor also stores a host of data
regarding performance and use of the
battery.
Several models available (see battery
monitor documentation).
VE.Bus to NMEA 2000 interface
Connects the device to a NMEA 2000 marine electronics
network. See the NMEA 2000 & MFD integration guide
MK3-USB VE.Bus to USB interface
Connects to a USB port (see ‘A guide to VEConfigure’)
Color Control GX
Provides monitor and control. Locally, and also remotely
on the VRM Portal.