Product Manual

18
5.4.2. DIP switch 2 to 6
These DIP switches can be used to set:
- Battery charge voltage and Absorption time
- Inverter frequency
- Search mode
Ds2-ds3: Setting the charge algorithm
ds2-ds3
Absorption
voltage
Float
voltage
Storage
Voltage
Absorption
Time
(hours)
Suitable for
ds2=off
ds3=off
(default)
14.4
28.8
57.6
13.8
27.6
55.2
13.2
26.4
52.8
8
Gel Victron Deep
Discharge
Gel Exide A200
AGM Victron Deep
Discharge
ds2=off
ds3=on
14.1
28.2
56.4
13.8
27.6
55.2
13.2
26.4
52.8
8
Gel Victron Long
Life (OPzV)
Gel Exide A600
(OPzV)
Gel MK battery
Li-ion (LiFePO4)
ds2=on
ds3=off
14.7
29.4
58.8
13.8
27.6
55.2
13.2
26.4
52.8
5
AGM Victron Deep
Discharge
Tubular plate or
OPzS batteries in
semi-float mode
AGM spiral cell
ds2=on
ds3=on
15.0
30.0
60.0
13.8
27.6
55.2
13.2
26.4
52.8
6
Tubular plate or
OPzS batteries in
cyclic mode
Ds4: Inverter frequency off = 50Hz on = 60Hz
Ds5: Search Mode off = off on = on