Installation Guide

10
5
8
7
3
6
1
2
9
Included
Rev.01
www.victronenergy.com
Quick Installation Guide MultiPlus-II
48V 5000VA 230Vac (hw rev 03 and above)
48V 3000VA 230Vac (hw rev 08 and above)
24V 3000VA 230Vac
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1
AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
>100mm
>100mm
>100mm
F
A
I
1
1
Battery
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1
AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1
AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
B
(T-sense)
K
(V-sense)
For fuse values:
refer to the user manual
Fuse (not included)
N
LPE
AC-IN 1
N LPE
L
N PE
AC-OUT 1 AC-OUT 2
2 3 4 5
8
6 7
7a 7b 7c 7d
6a 6b 6c 6d 6e 6f 6g 6h
1
Current
Sense
I
Terminals explanation
Read the manual
1 - Push button A
2 - Remote On/Off
3,4 - VE.Bus
5 - Current Sense
6 - a,b (+,-) K1
c,d (+,-) Ext. GND
e,f (+,-) Aux2
g,h (+,-) Aux1
7 - a,b (+,-) T-Sense
c,d (+,-) V-Sense
8 - Aux Relay
VE.Bus
H
J
4
G
F
B (T-sense)
A
Battery
Battery Cable -
Battery Cable +
AC-IN
AC-OUT
UTP-Cable
Remote control
E
F
H
I
L M
Current Transformer
J
G
Not included
D (5x)
C
L
N
E
N
M
IP21
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
www.victronenergy.com
MultiPlus
-
II
48 | 5000 | 70
AMP
VA
VOLT
AC transfer capacity: 50 A
|
Inverter 230 V
Battery
AC 0ut 2
AC 0ut 1AC in
temperature
low battery
overload
inverter on
inverter
float
absorption
bulk
mains on
charger
C
A
A
C
V-sense
K

Summary of content (1 pages)