3.5 Configuration of the controller
Fully programmable charge algorithm (see the software page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Note 1: divide all values by two in case of a 12V system.
Note 2: equalize normally off, see sect. 3.8.1 to activate
(do not equalize VRLA Gel and AGM batteries)
Note 3: any setting change performed with Bluetooth or via VE.Direct will
override the rotary switch setting. Turning the rotary switch will override prior
settings made with Bluetooth or VE.Direct.
Pos
Suggested battery type
Absorption
V
Float
V
Equalize
V
@%I
nom
dV/dT
mV/°C
0
Gel Victron long life (OPzV)
Gel exide A600 (OPzV)
Gel MK
28,2 27,6
31,8
@8%
-32
1
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
28,6 27,6
32,2
@8%
-32
2
Default setting
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
28,8 27,6
32,4
@8%
-32
3
AGM spiral cell
Stationary tubular plate (OPzS)
Rolls AGM
29,4 27,6
33,0
@8%
-32
4
PzS tubular plate traction
batteries or
OPzS batteries
29,8 27,6
33,4
@25%
-32
5
PzS tubular plate traction
batteries or
OPzS batteries
30,2 27,6
33,8
@25%
-32
6
PzS tubular plate traction
batteries or
OPzS batteries
30,6 27,6
34,2
@25%
-32
7
Lithium Iron Phosphate
(LiFePo
4
) batteries
28,4 27,0 n.a. 0