Product Manual

8
On all models with software version V 1.12 or higher a binary
LED code helps determining the position of the rotary switch.
After changing the position of the rotary switch, the LEDs will
blink during 4 seconds as follows:
Thereafter, normal indication resumes, as described below.
Remark: the blink function is enabled only when PV power is
present on the input of the controller.
3.6 LEDs
LED indication:
permanent on
blinking
off
Regular operation
LEDs
Bulk
Absorption
Float
Bulk (*1)
Absorption
Automatic equalisation (*2)
Float
Note (*1): The bulk LED will blink briefly every 3 seconds when the system is powered but
there is insufficient power to start charging.
Note (*2): Automatic equalisation is introduced in firmware v1.16
Fault situations
LEDs
Bulk
Absorption
Float
Charger temperature too high
Charger over-current
Charger or PV over-voltage
Internal error (*3)
Note (*3): E.g. calibration and/or settings data lost, current sensor issue.
Switch
position
LED
Bulk
LED
Abs
LED
Float
Blink
frequency
0
1
1
1
Fast
1
0
0
1
Slow
2
0
1
0
Slow
3
0
1
1
Slow
4
1
0
0
Slow
5
1
0
1
Slow
6
1
1
0
Slow
7
1
1
1
Slow