Product Manual

The table below indicates the charge algorithm and charge settings for each rotary switch position.
Rotary switch set to position 2
Turning the rotary switch will override the charge settings including settings that were made with the
VictronConnect App or with the display. Likewise, if charge settings are changed with the VictronConnect App
or the display, this will override the rotary switch setting.
Switch
position
Suggested
battery type
Absorption
voltage* (V)
Float
voltage*
(V)
Equalize**
voltage* (V)
Equalize**
nominal
current
percentage
Temperature
compensation
factor* (mV/°C)
0
Gel long life
(OPzV)
Gel Exide A600
(OPzV)
Gel MK
14.1
28.2
56.4
13.8
27.6
55.2
15.9
31.8
63.6
8%
-16
-32
-64
1
Gel Victron
deep discharge
Gel Exide A200
AGM Victron
deep discharge
Stationary
tubular plate
(OPzS)
14.3
28.6
57.2
13.8
27.6
55.2
16.1
32.2
64.4
8%
-16
-32
-64
2
Default setting
Gel Victron
deep discharge
Gel Exide A200
AGM Victron
deep discharge
Stationary
tubular plate
(OPzS)
14.4
28.8
57.6
13.8
27.6
55.2
16.2
32.4
64.8
8%
-16
-32
-64
3
AGM spiral cell
Stationary
tubular plate
(OPzS)
Rolls AGM
14.7
29.4
58.8
13.8
27.6
55.2
16.5
33.0
66.0
8%
-16
-32
-64
4
PzS tubular
plate traction
batteries or
OPzS batteries
14.9
29.8
59.6
13.8
27.6
55.2
16.7
33.4
66.8
25%
-16
-32
-64
5
PzS tubular
plate traction
batteries or
OPzS batteries
15.1
30.2
60.4
13.8
27.6
55.2
16.9
33.8
67.6
25%
-16
-32
-64
6
PzS tubular
plate traction
batteries or
OPzS batteries
15.3
30.6
61.2
13.8
27.6
55.2
17.1
34.2
68.4
25%
-16
-32
-64
* The top value is for 12V systems, the middle for 24V systems and the bottom for 48V systems.
** Equalize is by default disabled. To enable see chapter Battery settings [17]
MPPT solar charger manual
Page 15 Configuration and settings