Product Manual

- RX pin +5V will switch load output off
Load output on/off normal:
This setting allows load output on/off control:
- RX pin 0V will switch the load output off
- RX pin +5V will switch load output on
For more in depth "developer style" information on the VE.Direct port see the Data communication with Victron Energy products
Whitepaper.
5.3. Updating firmware
The firmware can be checked and updated with VictronConnect.
VictronConnect might ask on first connection to update firmware. If this is the case, let it perform a firmware update.
If it did not automatically update, check if the firmware is already up to date using the following procedure:
Connect to the solar charger
Click on the settings symbol
Click the option symbol
Go to product info
Check if you are running the latest firmware and look for the text: “This is the latest version”
If the solar charger does not have the most up to date firmware, perform a firmware update
5.4. VE.Smart network
The VE.Smart network allows a variety of products connected to the same network to share data via Bluetooth. The VE.Smart is
especially designed for smaller systems that do not have a GX device installed.
When the solar charger is part of a VE.Smart network it can receive data or communicate with the following devices:
All SmartSolar solar chargers
All BlueSolar solar charger that are connected to a VE.Direct Bluetooth Smart dongle.
The Smart Battery Sense
A BMV or SmartShunt battery monitor equipped with Bluetooth (or VE.Direct Bluetooth Smart dongle) and a optional BMV
temperature sensor.
Certain AC chargers
For the full compatibility list see theVE.Smart Product Compatibility list.
The VE.Smart network can be used for:
Temperature sensing - the measured battery temperature is used by the chargers in the network for temperature compensated
charging and in case of lithium battery for the low temperature cut off.
MPPT solar charger manual