Product Manual

22 Manual Skylla with universal input
The SKC panel:
This panel indicates if the charger is on or off, it indicates the charging mode and it
contains an adjustable potentiometer. Limiting the maximum charging current can
be useful to more accurately charge the batteries according the manufacturers
specifications, or to make sure the shore fuse does not blow.
To connect the panel:
Disconnect the mains.
Connect the on led to the “L_ON” connector.
Connect the boost led to the “ L_BO” connector.
Connect the float led to the “L_FL” connector.
Connect the ground of the panel to the “GND” connector.
Connect current control to the “+ POT” and “-POT” connector.
4.12 Connecting a remote on/off switch
A remote switch can be connected to the charger so the charger can be switched
on and off from a remote location. To operate the switch, first switch the charger
on with the on/off switch located on the charger.
To connect the remote on/off switch:
Disconnect the mains.
Connect the switch in between the “REM” and the “GND” connector.
4.13 Connecting a remote boost switch
A remote switch can be connected to the charger so the charger can be switched
permanently into the boost-charge mode. Due to parallel loads connected to the
battery it is advised to switch the charger into the permanent boost-charging mode
in order not to discharge the battery.
If the switch is closed the charger switches into the permanent boost-charge
mode. If the switch is opened again the charger will automatically go to the float-
charge mode. This in order not to overcharge a battery with charging it to long with
higher charging voltage.
To connect the boost switch:
Disconnect the mains.
Connect one pole of the switch to the “RBOO” connector.
Connect the other pole of the switch to the “GND” connector.