Product Manual

Scrolling text Icons Segments Units Function or parameter
20 TEMPERATURE
COMPENSATION
-3.0-2.7-0.0
°C mV Battery temperature
compensation per cell
22 BULK TIME PROTECTION
OFF10
A Bulk time protection
23 MAXIMUM ABSORPTION
TIME
1.0-8.024.0
h Absorption time
24 STORAGE MODE
On, OFF
Storage mode
25 MAXIMUM FLOAT TIME 4.0-8.0-24.0
h Maximum float time
26 REPEATED ABSORPTION
TIME
0.5-1.0-24.0
h Repeated absorption time
27 REPEATED ABSORPTION
TIME INTERVAL
0.5-7.0-45
Day Repeated absorption
interval
LOW TEMPERATURE CHARGE
CURRENT
0.0-60.0
A Low temperature charge
current
29 LOW TEMPERATURE
CHARGE CURRENT
0.0-100.0-0.0
A Max. charge current below
the low temperature level
(item 30)
30 CHARGE OFF,ON
Watch function (start-up in
storage if battery voltage
>>13 V
30 LOW TEMPERATURE
LEVEL
-10.0-5-10.0
°C Low temperature level (for
item 29)
31 BMS PRESENT
BMS y,n
BMS Present
33 POWER SUPPLY VOLTAGE 8.0-12.0-15.9
V Power supply voltage
34 INPUT CURRENT LIMIT
1c 0.0-12.
0
A Input current limit
49 BACKLIGHT INTENSITY
0-5-9
The intensity of the
backlight
50 BACKLIGHT RELAYS ON OFF,ON, AUTO
Backlight automatic turn off
after 60s
51 SCROLL SPEED
1-3-5
Text scroll speed
52 Buzzer
y n
Buzzer
60 CAN DEVICE INSTANCE
dl 0-255
VE.Can device instance
61 SOFTWARE VERSION 1.00
Software version
62 RESTORE DEFAULTS
rESEt
System reset to default
settings
63 CLEAR HISTORY
CLEAr
History data reset
64 LOCK SETUP
LOCK y,n
Lock setting
67 TEMPERATURE UNIT
CELC,FAhr
Temperature unit °C/°F
After entering the setup menu, the user can scroll through the menu with the up/down keys.
With select a menu item is entered and the present value is shown. With the up/down keys the user can scroll through the
available modes or increase/decrease the value.
By pressing select again the value/item is set.
Pressing setup shortly will return to the setup menu.
When setup is completed, exit the menu by pressing “SETUP” again three seconds.
Skylla-IP65
Page 8 Control and Adjustment