Product Manual

8. Specifications
Skylla-IP65 12/70 24/35
Input voltage (VAC) 120 – 240
Input voltage range (VAC)
(1)
90 – 265
Maximum AC input current 12
Frequency (Hz) 45-65
Power factor 0,98
Charge voltage 'absorption'
(VDC)
(2)
See table See table
Charge voltage 'float' (VDC)
(2)
See table See table
Charge voltage ‘storage’ (VDC)
(2)
See table See table
Charge current main batt. (A)
(3)
70 35
Charge current starter batt. (A)
(4)
3 4
Charge curve, lead-acid 7 stage adaptive
Recommended battery capacity
(Ah)
350-700 150-350
Charge curve, Li-Ion 2 stage, with on-off control or VE.Can bus control
Temperature sensor Yes
Power supply function Yes
Remote on-off port Yes (can be connected to a Li-Ion BMS)
CAN bus communication port Two RJ45 connectors, NMEA2000 protocol
Remote alarm relay
DPST AC rating: 240 VAC/4A DC rating: 4A up to 35 VDC, 1 A up to 60 VDC
Forced cooling Yes
Protection
Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to 60 °C (full output current up to 40 °C)
Humidity (non-condensing) max 95 %
ENCLOSURE
Material & Colour steel; blue, RAL 5012
Battery-connection M6 bolts
Mains connection screw-clamp 6 mm² (AWG 10)
Protection category IP65
Weight kg (lbs) 6 (14)
Dimensions hxwxd incl. glands in
mm in inches
401 x 375 x 265
(16 x 15 x 10.5)
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
1) Output current will gradually reduce below 110
V to 50 % @ 100 V
2) Depending upon battery type as selected in the
setup menu.
3) Maximum current up to 40 °C (100 °F) ambient. Output current
will reduce to 60 % at 50 °C, and to 40 % at 60 °C.
4) Depending upon state of charge of starter battery
Skylla-IP65
Page 16 Specifications