11.6 Physical and Environmental
11.6.1 Power Requirements
Power supply switch set to 115V Power supply switch set to 230V
Voltage 90-135 Vac 47-63Hz 180-265 Vac 47-63Hz
Current 2A maximum 1A maximum
11.6.2 CE Marking
This product is CE marked. It has been fully tested and complies with 89/336/EEC
Electromagnetic Compatibility and 73/23/EEC Low Voltage directives, and with EN
60950:2000 safety standards.
Warning: This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
11.6.3 Dimensions and Weight
Width Height Depth Weight
Unit 165mm 200mm 310mm 6Kg
Packaged 275mm 380mm 475mm 8Kg
11.6.4 Temperature and Humidity
Operating Storage
Temperature 10 to 35 º C -20 to 60 º C
Humidity 5 to 95% non-condensing 5 to 95% non-condensing
11.6.5 Ventilation
The Ai150 Digital Recorder has ventilation holes in the base, front and rear. Using internal
fans, the unit creates a continuous flow of air through the unit to control the temperature of
the disc drives and other internal components.
The ventilation holes must not be obstructed otherwise the lifetime and reliability of the
system may be affected.
11.6.6 Safety
For warranty and safety reasons, the cover of this equipment must not be removed. There
are no user serviceable parts inside.