You can tick the option by default this option is ticked already Copy Name/Mask/Viewstyle to the corresp.
detectors to make sure that all modifications are automatically copied to the corresponding detectors.
How many inputs from the same detector you can configure, depends on the type of the fire detector. Please
consult the technical documentation of the specific detector for more information.
13.3.1 Fire Reset Input and Output (SmokeTrace Stop Input)
You can configure an input as fire reset input. This means that when this input is activated an output will be
activated as a consequence. The output will reset all fire detectors.
To define the fire reset output, proceed as follows:
1. Select an output from the list.
2. Set Behaviour to Programmable.
3. Select SmokeTrace Stop (I202) in the list.