User Manual

Videoswitch 11 Pos601a.doc
Vi-POSCON Installation Guide
Video Input Jumper Notes
1 JP5
2 JP4
3 JP3
4 JP2
AUX JP1
For future use
[J] Video Output (1 through 4) – four BNC connectors for video output. The video output signals
include the text overlay from the EPoS.
4.3 The Vi-POSCON Text Overlay
The monitor text overlay of the Vi-POSCON System is similar to the following illustration. The
surveillance scene is omitted for clarity.
The 3-part text line at the top of the monitor screen displays:
The time in either 12-hour or 24-hour format,
Up to 20 characters for the store's identifier, and
The date in DD/MM/YY, MM/DD/YY, or YY/MM/DD format. (Note: the system replaces the date
separator "/" with "." for the German, Polish, Finnish, Hungarian, Czechoslovakian and Russian
languages, and "-" for the Portuguese and Danish languages.)
The Transaction window displays all register transactions as they occur. The window displays a
maximum of 40 characters per line (38 characters if an outline border is selected). A 12-character
register name box is displayed at the top of the Transaction window.
In the Surveillance Mode, the Channel Bar at the bottom of the screen displays numbered boxes to
indicate the activated video input channels. The example in the above figure shows three activated
channels with Channel 3 being monitored (highlighted). When an event occurs, the system switches
to the channel reporting the event, and its box highlights.
When an Alarm (External) event occurs, the Store Identifier is replaced by a highlighted, flashing
ALARM # (where # = the number of the Alarm) or the Alarm Identifier text (if entered, for example:
DOOR). At the end of the event duration, the Store Identifier is restored.
HH:MM:SS Store Identifier DD/MM/YY
Orange Juice 0.89
Whole Milk 1.23
Skimmed Milk 1.18
Baked Beans 0.26
4 Items 3.56
Tax 0.21
Total 3.77
Cash 5.00
Change 1.23
Register 3
1
2
3
Transaction
window
Channel Bar