User manual

Digital Recorder
9
1.10 Critical Alerts
The ViX05 constantly monitors the hard drive, camera inputs and system so that detected
fault conditions will be reported to the user as soon as possible by means of a “critical alert”
message on the screen. Alerts are also added to the event list.
FailTest This alert indicates that the self-test has failed – try the
following
Press the HELP key then the MON key twice, to call up the
“INFO-2 Status” screen. One of a number of fault
conditions may be noted.
If a checksum error is reported, enter the menu, change
any setting and return to LIVE mode so that settings are
saved. Try changing a password also.
Switch off the ViX05, wait 10 seconds and switch on again.
Try a power-on reset
If the problem persists, contact your supplier.
HD1, 2,3 Fail This alert indicates that a hard drive is not working.
Check that the drive drawers are correctly fitted
Check the lock in the drive drawer is turned full counter-
clockwise
Press the HELP key then the MON key three times, to call
up the “INFO-3 Drives” screen. Press OK to rescan the
drives.
Check the DISC ACTIVITY LED is flickering
Check that the red DISC POWER led it lit.
HD1, 2,3 SMART This alert indicates that the hard drive may stop working soon
The SMART monitoring detects imminent failure of a hard
drive, so if this warning occurs, the drive should be
changed at the earliest opportunity.
To cancel a critical alert, press the FIND key several times until the “FIND-3 Event
screen is displayed.
FIND
View the recent alerts (press TAG to see latest). Press OK to cancel critical alerts.
Note that if the alert condition persists, the alert message will re-appear.
Intelligent Security and Fire Ltd