I N S T A L L A T I O N / O P E R A T I O N M A N U A L HIGH DEFINITION PLASMA DISPLAYS Models VP-5000VHD, VP-5000VHDa, VP-6500VHD, VP-6500VHDa and VP-103VHD
THREE YEAR LIMITED WARRANTY For Plasma Displays from Vidikron, a business of Runco International, LLC (“Vidikron”) Congratulations on your purchase of a Vidikron video product and welcome to the Vidikron family! With proper installation, setup and care, you should enjoy many years of unparalleled video performance. WHAT IS COVERED UNDER THE TERMS OF THIS LIMITED WARRANTY: Y This is a LIMITED WARRANTY as defined in the Magnuson-Moss Warranty Act.
CAUTION: THIS LIMITED WARRANTY ONLY COVERS VIDIKRON PRODUCTS PURCHASED FROM AUTHORIZED VIDIKRON DEALERS. ALL OTHER PRODUCTS ARE SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS WARRANTY. MOREOVER, DAMAGE RESULTING DIRECTLY OR INDIRECTLY FROM IMPROPER INSTALLATION OR SETUP IS SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED WARRANTY. IT IS IMPERATIVE THAT INSTALLATION AND SETUP WORK BE PERFORMED ONLY BY AN AUTHORIZED VIDIKRON DEALER TO PROTECT YOUR RIGHTS UNDER THIS WARRANTY.
COPYRIGHT AND TRADEMARKS: © Copyright 2008 Runco International, LLC (“Runco”). This document contains proprietary information protected by copyright, trademark and other intellectual property laws. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic or other means, in any form, without prior written permission of Runco. The trademarks reporduced in this Vidikron Owner’s Manual and used on the Vidikron Products are either owned by Runco or are licensed by Runco.
Important Safety Instructions Thank you for your purchase of this quality Vidikron video product! It has been designed to provide you with the quality of video that is expected in a home theater. For the best performance, please read this manual carefully as it is your guide through the menus and operation.
Compliance Information DECLARATION OF CONFORMITY: Manufacturer’s Name: Runco International, LLC Manufacturer’s Address: 1195 NW Compton Drive, Beaverton, OR 97006-1992 conform with the provisions of: EL IM IN A R VP-5000VHD, VP-5000VHDa, VP-6500VHD, VP-6500VHDa and VP-103VHD Y hereby declares that the Products’ Model Numbers: Council Directive 2004/108/EC on Electromagnetic Compatibility; EN 55022 “Limits and methods of measurements of radio interference characteristics of information technology equi
FCC PART 15: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Table of Contents 1 THREE YEAR LIMITED WARRANTY .......................................................................................... iii Important Safety Instructions ................................................................................................. vi Compliance Information ......................................................................................................... vii 1. Introduction .......................................................................................
Table of Contents Connections to the PlasmaView VHD and VHD Controller ..............................................................22 Connecting the PlasmaView VHD to the VHD Controller .........................................................22 Connecting Source Components to the VHD Controller ..........................................................24 RS-232 Controller Connection ............................................................................................................
1 List of Figures 2-1. PlasmaView VP-5000VHD Front-Panel Controls and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2-2. PlasmaView VP-6500VHD Front-Panel Controls and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2-3. PlasmaView VP-103VHD Front-Panel Controls and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2-4. PlasmaView VHD Rear Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Figures PR EL IM IN A R Y Notes: xii Vidikron PlasmaView VHD Installation/Operation Manual
1 This Owner’s Manual describes how to install, set up and operate a Vidikron PlasmaView VHD High-Definition Plasma Display (Model VP-5000VHD, VP-5000VHDa, VP-6500VHD, VP-6500VHDa or VP-103VHD). Introduction 1.1 About This Manual EL IM IN A R Y Throughout this manual, the Vidikron PlasmaView VHD High-Definition Plasma Display is referred to simply as the “PlasmaView VHD.” Except where otherwise indicated, the information in this manual applies to all PlasmaView VHD models.
Introduction Graphic Conventions: These symbols appear in numerous places throughout the manual, to emphasize points that you must keep in mind to avoid problems with your equipment or injury: TIPS highlight time-saving short cuts and helpful guidelines for using certain features. Note NOTES emphasize text with unusual importance or special significance. They also provide supplemental information.
Introduction The PlasmaView VHD High-Definition Plasma Display establishes a higher threshold for flat panel display products. The PlasmaView VHD is available in three sizes, including our largest and highest-resolution plasma ever, at 103 inches diagonal and 1920 x 1080 (1080p) native resolution. 1.
Introduction Parts List ➤ Your PlasmaView VHD is shipped with the following items. If any items are missing or damaged, please contact your Vidikron dealer or Vidikron Customer Service at (888) 4VIDIKRON (484-3457). • PlasmaView VHD High-Definition Plasma Display • AC Power Cords (2) • Remote Control Unit and two (2), AAA-size batteries • RJ-11 Telephone Cable, 50 feet (15.
Controls and Functions 2 2.1 PlasmaView VHD at a Glance 2 (behind front bezel) EL IM IN A R Y Figure 2-1, Figure 2-2 and Figure 2-3 show the PlasmaView VHD front-panel controls and indicators. 4 3 PR 1 Figure 2-1. PlasmaView VP-5000VHD Front-Panel Controls and Indicators 3 4 2 (behind front bezel) 1 Figure 2-2.
Controls and Functions 4 3 EL IM IN A R Y 2 1 Figure 2-3. PlasmaView VP-103VHD Front-Panel Controls and Indicators DISPLAY STAND Optional accessory for table-top installations. 2. POWER BUTTON Connects or disconnects the display panel from the AC power source. 3. STANDBY/ON INDICATOR - Lights green to indicate normal operation; - Lights red to indicate that the PlasmaView VHD is in standby mode. 4. REMOTE CONTROL SENSOR Receives the signals from the remote control. PR 1.
Controls and Functions Figure 2-4 shows the rear-panel connector locations on the PlasmaView VHD. VP-5000VHD Connectors EL IM IN A R Y 5 VP-6500VHD PR 5 VP-103VHD 5 A B AUDIO AV IN SLOT1 SLOT2 1 2 PC 3 Figure 2-4.
Controls and Functions SLOT 1 Not used. 2. SLOT 2 (Dual HDMI input) HDCP-compliant digital video inputs. Connect the HDMI output from the VHD Controller to input “A” in this slot. 3. PC IN Not used. 4. RS-232C (9-pin, male D-Sub) Connect the RS-232 OUT port on the VHD Controller to this input. 5. POWER INPUT Connect the PlasmaView VHD to AC power here. 2.2 VHD Controller Front Panel EL IM IN A R Y 1.
Controls and Functions 2.3 VHD Controller Rear Panel Figure 2-6 shows the rear connector panel on the VHD Controller. 7 3 9 SYSTEM CONTROL INTERFACE CAUTION INPUTS Serial No R/Pr G/Y B/Pb RISK OF ELECTRIC SHOCK DO NOT OPEN H V ! AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR TRIGGERS CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER.
Controls and Functions 9. IR Wired input from a wired remote control or infrared receiver. It is a 3.5-mm, mini phono jack, wired as follows: Ring = +5V Tip = IR Input Sleeve = Ground Note When an external remote control or infrared receiver is connected to the wired IR input, the IR sensor on the front of the VHD Controller is disabled. Y 10. RS-232 CONTROL PORT A female, 9-pin D-sub connector for interfacing with a PC or home theater automation/control system. EL IM IN A R 11.
Controls and Functions Figure 2-7 shows the VHD Controller remote control, and the paragraphs that follow describe its functionality. 1 2 Y 3 6 8 9 12 13 15 17 18 7 10 (“CUST 2” on some models) 11 14 16 PR 5 EL IM IN A R 4 19 22 20 21 Figure 2-7. VHD Controller Remote Control Vidikron PlasmaView VHD Installation/Operation Manual 11 2.
Controls and Functions 1. IR OUTPUT INDICATOR Lights when a button is pressed to indicate that an IR signal is being transmitted. 2. LIGHT Press to illuminate the buttons. 3. ON / OFF Press to turn the projector on or off. 4. ENT (Enter) Press to select a highlighted menu item or confirm a changed setting. Y On some remote control units, this button is where the RETURN/EXIT button (item #6) appears here. EL IM IN A R Note 5.
Controls and Functions Memory Preset Buttons: 8. ISF NT (Night) Press to recall settings for the current input from the “ISF Night” memory preset. 9. ISF DAY Press to recall settings for the current input from the “ISF Day” memory preset. 10. THX (VP-6500VHD) / CUST 2 (all other models) Press to recall settings for the current input from the “Custom 2” or “THX” memory preset. 11. CUST 1 Press to recall settings for the current input from the “Custom 1” memory preset. Y 12.
Controls and Functions PR EL IM IN A R Y Notes: 14 Vidikron PlasmaView VHD Installation/Operation Manual
3 To install batteries in the remote control: 1. Press down the tab on the cover and pull the cover in the direction of the arrow. 2. Insert the included batteries. Ensure that the polarities correctly match the markings inside the battery compartment. 3. Insert the lower tab of the cover into the opening, and press down the cover until it clicks in place. Installation 3.1 Remote Control EL IM IN A R Y and • When installing batteries, make sure that the battery polarities are correct.
Installation • Do not drop the remote control or expose it to moisture or high temperature. • The remote control may malfunction under a fluorescent lamp. If that occurs, move the plasma display away from the fluorescent lamp. • Make sure that there is nothing obstructing the infrared beam between the remote control and the IR receiver on the plasma display. Note The signal from the remote control can be reflected by walls or other surfaces.
Installation Table 3-1 gives a quick overview of the PlasmaView VHD installation process. The sections following this one provide detailed instructions. Note Installation should be performed by a qualified custom video installation specialist. For Details, refer to page... Procedure EL IM IN A R Step Y Table 3-1.
Installation 3.3 Installation Considerations Special Requirements for the ➤ VP-103VHD Proper installation of your PlasmaView VHD will ensure the highest possible picture quality, protect your investment and prevent personal injury. Whether you are installing the PlasmaView VHD temporarily or permanently, you should take the following into account to ensure that it performs optimally.
Installation You can attach your optional mounts or stand to the PlasmaView VHD in either of two ways: EL IM IN A R Y • While it is upright. • As it lies flat with the screen face down. Place the protective sheet, which was wrapped around the plasma monitor when it was packaged, between the screen and your work surface to avoid scratching or otherwise damaging the screen surface. PR In general, minimize or eliminate light sources directed at the display.
Installation Wall 50mm (2") 50mm (2") Wall 50mm (2") 50mm (2") EL IM IN A R Y 50mm (2") Figure 3-2. Ventilation Requirements for Enclosure Mounting (VP-5000VHD and VP-6500VHD) 300mm (11.8") 300mm (11.8") PR 300mm (11.8") 300mm (11.8") Wall Wall 200mm (7.87") Figure 3-3.
Installation Other considerations and tips that can help improve your installation, avoid damage and prolong operating life: • Keep the ambient temperature constant and below 35°C (95°F). Keep the display away from heating and/or air conditioning vents. Changes in temperature may cause drifts in the display circuitry, which may affect performance. • Keep the PlasmaView VHD away from devices that radiate electromagnetic energy such as motors and transformers.
Installation 3.4 Connections to the PlasmaView VHD and VHD Controller Proceed as follows to connect the PlasmaView VHD to the VHD Controller, your video sources, external controller(s) – if present – and AC power. When connecting your equipment: • Turn off all equipment before making any connections. • Use the correct signal cables for each source. • Ensure that the cables are securely connected. Tighten the thumbscrews on connectors that have them.
Installation RS-232 Connection: Connect the RS-232 output from the VHD Controller to the SERIAL input on the PlasmaView VHD. Use a standard, modular telephone cable with RJ11 plugs at both ends. On the PlasmaView VHD end, use the provided RJ11-to-DB9 adapter. This adapter is wired as shown in Figure 3-5.
Installation Connecting Source ➤ Components to the VHD Controller Connect your video sources to the VHD Controller as shown and described in the sections that follow. HDMI Connections: See Figure 3-6. Use the HDMI inputs whenever possible. This ensures the highest video quality because the signal is carried in the digital domain throughout the entire signal path, from source component output into the projector.
Installation Digital (DTV) RGB Connections: See Figure 3-7. R/Pr G/Y INPUTS B/Pb H V TRIGGERS HD1 1 2 3 HD2 R/Pr G/Y B/Pb H V S-Video 1 Pb HDMI 2 Pr Y Component Video Video S-Video 2 DTV or Progressive Component (YPbPr) Source Horiz Vert PR Red/Pr Green/Y Blue/Pb EL IM IN A R Y HDMI 1 Figure 3-7.
Installation Analog (Computer) RGB Connections: See Figure 3-8. 1. Refer to PlasmaView VHD Specifications on page 61 for a list of computer signals compatible with the PlasmaView VHD. Use with signals other than those listed may cause some functions not to work. Note 2. Some Macintosh computers may require a Macintosh video adapter. Contact your nearest authorized service center or dealer.
Installation Composite/S-Video/Component Video Connections: See Figure 3-9. R/Pr G/Y INPUTS B/Pb H V TRIGGERS HD1 1 2 3 HD2 R/Pr G/Y B/Pb H V S-Video 1 HDMI 2 Pb Y Pr Component Video Video S-Video 2 EL IM IN A R Y HDMI 1 Pr Y PR Pb DVD Player, VCR, Satellite Receiver, Laser Disc etc. Figure 3-9.
Installation RS-232 Controller ➤ Connection Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation system (if present) to the RS-232 Control port on the VHD Controller; see Figure 3-10. For more information about using this connection, refer to Serial Communications on page 55.
Installation If infrared signals from the remote control cannot reach the VHD Controller due to excessive distance or obstructions such as walls or cabinet doors, you can connect an external IR receiver to the VHD Controller to extend the range of the remote control. See Figure 3-12. SYSTEM CONTROL INTERFACE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ! AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR TRIGGERS 1 2 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER.
Installation Connecting AC Power ➤ Plug the female end of the power cord into the AC receptacle on the rear of the PlasmaView VHD. Connect the other end to your AC power source. (The VP-103VHD requires 200 – 240 VAC.) EL IM IN A R Y VP-5000VHD PR VP-6500VHD VP-103VHD (NOTE: The VP-103VHD requires 200 - 240 VAC) Figure 3-13. AC Power Connection Similarly connect the VHD Controller to a nearby AC outlet.
Installation To reduce cable clutter, use the cable clamps provided with the PlasmaView VHD to bundle the video, audio and control cables at the back of the display. Install the clamps as shown in Figure 3-14. Securing the AC cord to the rear of the panel (VP-5000VHD) 2. Insert the AC cord and close the clamp securely. 1. Open the clamp. Clamp 4. Insert the end of the clamp band into the small hole on the lower right of the back cover. 3. Slide the clamp upward to secure the AC cord.
Installation PR EL IM IN A R Y Notes: 32 Vidikron PlasmaView VHD Installation/Operation Manual
4 Turn on your source components. 2. Press the main power switch at the front of the PlasmaView VHD (see Figure 2-1). The standby/on indicator lights green. 3. Set the main power switch at the rear of the VHD Controller (see Figure 2-6) to the “on” position. 4. Press the ON button on the remote control to turn on the VHD Controller and PlasmaView VHD (or press the power button on the front of the VHD Controller). The power indicator on the VHD Controller lights solid blue. EL IM IN A R 5.
Operation Double click on the Display icon. 3. Click the Settings tab on the display dialog box. 4. Set the Screen area to 1024x768 pixels. EL IM IN A R Y 2. PR 5. Click the Advanced button and click the Monitor tab on the dialog box. Set the Refresh Frequency to 60Hz and click OK. Note 1. The native resolution of the PlasmaView VHD is 1920 x 1080. Other horizontal or vertical resolutions may be scaled upward or downward to fit the display. 2.
Operation Press the MENU button on either the remote control or the VHD Controller front panel to display the Main Menu. To select a menu item, use the UP ( ) and DOWN ( ) buttons on either the remote control or the VHD Controller front panel to highlight it. Press ENTER to confirm your selection. The PlasmaView VHD OSD menus are arranged hierarchically, as shown in Figure 4-1. Depending on the selected input source and signal characteristics, some menu options may not be available.
Operation Picture Input Position Memory Presets Information PR (read-only) ISF Night - Input Image ISF Night - Input Color Y Aspect Ratio ISF Night - Display Color EL IM IN A R Input Source Composite S Video 1 S Video 2 Component SD HD/RGB 1 HD/RGB 2 HDMI 1 HDMI 2 16:9 4:3 Letterbox IntelliWide Cinema Brightness Contrast Color Tint Sharpness Left/Right Up/Down Width Height Overscan Recall ISF Night Recall ISF Day Recall or Save Custom 1 Recall or Save THX/Custom 2 Reset Custom 1 and THX/Custom
Operation The Main Menu is the starting point for accessing all display functions. Main Menu (The Calibration and Service menus are hidden and not accessible until you enter a passcode.) Vidikron Video Input Source Aspect Ratio Picture Input Position Memory Presets Information Calibration EL IM IN A R From the Main Menu, select Input Source to choose a video signal source. Y Service The active source is indicated by an arrow (>) to its left; in this example, Composite is the active source.
Operation Table 4-1. Aspect Ratio Settings Aspect Ratio Remote Control Key 16:9 16:9 Description Select 16:9 to view 16:9 DVDs and HDTV programs in their native aspect ratio. EL IM IN A R Y 16:9 Image on 16:9 Screen (Display) 4:3 images are stretched horizontally to fit a 16:9 screen.
Operation Use the controls in the Picture Menu to calibrate the analog inputs on the PlasmaView VHD for optimum picture quality. Picture Picture Note To calibrate the digital (HDMI 1 and HDMI 2) inputs, use the Display Image controls in the Service menu. For more information, refer to Display Device on page 47. Y The PlasmaView VHD has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF).
Operation PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes. Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that: • The darkest black bars disappear into the background. • The dark gray areas are barely visible. • The lighter gray areas are clearly visible. • The white areas are a comfortable level of true white.
Operation EL IM IN A R Y blue red magenta green cyan yellow gray Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint blue red magenta green cyan PR yellow gray Select Color and press ENTER.
Operation EL IM IN A R Y Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them. Figure 4-5.
Operation Overscan: Image Overscan pushes the outside edge of the active picture area of the video signal out beyond the edge of the display area. Some television programs are produced based on the assumption that older television sets may not display the outer edges of the broadcast picture area. Over scan effectively trims away these inactive, outer edges and enlarges the remaining portion of the image to fill the display area. Select from 1% to 10% of Overscan, as desired.
Operation Calibration ➤ Use the Calibration menu to perform advanced picture quality adjustments on the analog inputs. This menu should be used by ISF-certified technicians only. Calibration ISF Night Note Display Color Input Image Input Color ISF Day Note To calibrate the digital (HDMI 1 and HDMI 2) inputs, use the Display Image controls in the Service menu. For more information, refer to Display Device on page 47. You must enter a passcode to access the Calibration menu.
Operation ISF Night - Input Color: The Input Color controls are similar to those in the Display Color menu (see above), but adjust the color balance at the VHD Controller (as opposed to the display device). These settings are also saved independently for each input. • Gain/Offset: These controls operate similarly to those in the ISF Night - Display Color menu (see above), but affect the Y, Pb and Pr signal components rather than the red and blue channels.
Operation • Vidikron/ISF Logo Splash Screen Timers: When you turn on the PlasmaView VHD, it projects a welcome screen with the Vidikron logo followed by one with the ISF logo. Select Splash Timer from the Splash Configure menu to set the amount of time that these two images appear. The range is from 2 to 60 seconds, in one-second increments. Use the up or down cursor button to select a timer value to adjust. Use the right or left cursor button to change the timer value.
Operation • You have multiple VHD Controllers and want to control them independently, as opposed to broadcasting commands from a single remote to all of them. In this scenario, you can use multiple remotes programmed to use different IR codes. Or, you can use a single remote and change the IR code as needed to address a specific device. Tip Do not change the “Type” setting in this menu. Y Note Use the VHD Controller front-panel keypad to change its IR code.
Operation • Display Image (1080i digital and 1080p signals ONLY): Select Display Image from the Display Device menu to perform the following display device adjustments. • Brightness • Contrast • Color • Tint • Sharpness • Color Temperature • Input Level • Red/Green/Blue Gain EL IM IN A R • Red/Green/Blue Offset Y • AGC • Gamma For detailed instructions for making these adjustments, refer to Picture on page 39 or Calibration on page 44.
Operation Miscellaneous: Select Miscellaneous from the Service menu to set the following options: • Language: Select Language from the Miscellaneous menu and press the up- or down-arrows to select the OSD language. (Currently, only English is supported.) • Menu Mode: This is the manner in which the OSD menus appear and disappear when you press MENU. Choose one of the following: 0 = No transition; menus abruptly appear and disappear. 1 = Menus fade in and out.
Operation PR EL IM IN A R Y Notes: 50 Vidikron PlasmaView VHD Installation/Operation Manual
5 Maintenance and Troubleshooting Regular cleaning will extend the life and performance of the PlasmaView VHD. Before cleaning, be sure to unplug the power cord from the power outlet. Do not under any circumstances use solvents such as benzene or thinner to clean the PlasmaView VHD. Doing so may cause deterioration or peeling of paint from the display or remote control unit. 5.
Maintenance and Troubleshooting 5.2 Troubleshooting Tips Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the PlasmaView VHD. If the suggested solutions fail to resolve the problem or if you encounter an issue not described here, please contact your Vidikron dealer or Vidikron Technical Support. Table 5-1. Troubleshooting Chart Possible Cause(s) The display does not turn on after initial installation.
Maintenance and Troubleshooting Table 5-1. Troubleshooting Chart (continued) Symptom Possible Cause(s) Solution • Clock and Phase settings need adjustment. • Adjust Clock and Phase settings (refer to ISF Night Input Color on page 45). Computer images do not display correctly. • The resolution and frequency of the video card in the computer are not compatible with the PlasmaView VHD. • Select a compatible resolution and vertical frequency (refer to Supported Timings on page 66).
Maintenance and Troubleshooting PR EL IM IN A R Y Notes: 54 Vidikron PlasmaView VHD Installation/Operation Manual
Serial Communications 6 To interface the PlasmaView VHD with a home theater automation/control system or a PC running terminal emulation software, connect it to the RS-232 output of the VHD Controller as shown in Figure 3-5. Connect your control system or PC to the RS-232 input of the VHD Controller as shown in Figure 3-10. 6.
Serial Communications Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the VHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the VHD Controller ignores it and returns a minus sign (- >). Table 6-1.
Serial Communications Table 6-1.
Serial Communications Table 6-1.
Serial Communications Table 6-1.
Serial Communications Table 6-1. Serial Commands (continued) Command Parameter (min/max) Value Stored? Description The following serial commands are meant to emulate buttons on the remote control or VHD Controller front panel. Each button has its own serial command, so effectively it is as if you were using the IR remote only you’ll be doing so via serial commands. These commands provide active OSD responses just like the IR remote.
7 7.1 PlasmaView VHD Specifications Table 7-1 lists the PlasmaView VHD specifications. 1920 x 1080 Screen Size: VP-5000VHD / VP-5000VHDa: 43.50 in. W x 24.50 in. H (1104.9 x 622.3 mm) 50 in. (1270.0 mm) diagonal VP-6500VHD / VP-6500VHDa: 56.50 in. W x 31.80 in. H (1434.0 x 807.0 mm) 65 in. (1646.0 mm) diagonal VP-103VHD: 89.30 in. W x 50.30 in. H (2268.2 x 1277.6 mm) 103 in. (2616.
Specifications Table 7-1. PlasmaView VHD Specifications (continued) Limited Warranty: Three (3) years parts and labor from the date of delivery to the end user (except for plasma glass panel). Plasma Glass Panel: One (1) year parts and labor from the date of delivery to the end user. Regulatory Approvals: Complies with FCC Part 15 Class B, ICES-003, UL6500 Ver.2 EL IM IN A R Table 7-2 lists the VHD Controller specifications. PR 7.
Specifications Figure 7-1, Figure 7-2 and Figure 7-3 show the PlasmaView VHD dimensions (all dimensions are in inches). 14.0 0.9 29.2 2.1 32.4 EL IM IN A R 31.5 50.4 20.5 48.4 Y 2.5 1.3 PR 6.9 12.6 11.5 26.0 Figure 7-1. PlasmaView VHD Model VP-5000VHD Dimensions (with Optional Table Stand) Vidikron PlasmaView VHD Installation/Operation Manual 63 7.
Specifications 14.0 37.1 34.9 18.5 2.2 1.0 0 2.9 0 2.2 7.1 8.5 9.7 EL IM IN A R Y 47.7 59.3 30.9 59.7 61.9 5.5 6.4 37.1 28.9 23.6 10.6 0 2.9 PR 4.1 5.6 36.2 2.0 0 9.8 18.0 42.7 52.0 61.9 Figure 7-2.
Specifications 50.75 6.50 1.45 34.30 EL IM IN A R PR 5.25 42.30 Figure 7-3. PlasmaView VHD Model VP-103VHD Dimensions (with Floor Stand) Vidikron PlasmaView VHD Installation/Operation Manual 65 59.50 89.38 96.13 102.50 69.40 Y 16.
Specifications 7.4 Supported Timings Table 7-3 lists the signal types supported by each input on the VHD Controller. Table 7-3. Supported Signal Timings by Input Supported? (√ = Yes, – = No) 800x600 1024x768 1024x768 Component S-Video 1 S-Video 2 Video – – – – – – – – – – – – 60.00 31.469 25.175 √ 72.00 37.861 31.500 √ 75.00 37.500 31.500 √ 85.00 43.269 36.000 √ – – – – 56.00 35.156 36.000 √ – – – – 60.00 37.879 40.000 √ √ – – – 72.00 48.077 50.
Specifications Table 7-3. Supported Signal Timings by Input (continued) Supported? (√ = Yes, – = No) Format Resolution Refresh Rate (Hz) Horizontal Pixel Frequency HD/RGB 1 Frequency (kHz) (MHz) HD/RGB 2 HDMI 1 HDMI 2 Component S-Video 1 S-Video 2 Video – 50.00 15.625 3.580 √ – √ √ √ PAL-60 – 59.94/60.00 15.734/15.750 4.
Specifications PR EL IM IN A R Y Notes: 68 Vidikron PlasmaView VHD Installation/Operation Manual
020-0781-01 Rev. A March 2008 1-888-4-VIDIKRON Fax 503-748-8161 www.vidikron.