PEX Installation

Table Of Contents
IM-PF 724596 0416
34
13.3
Mounting the ManaBloc - surface mount
1. A suitable base for the ManaBloc can be
constructed from a section of ½" or thicker
plywood that is a minimum 22½" wide and slightly
longer than the overall length of the ManaBloc.
2. Securely attach a length of 2x4, or other suitable
framing material with a thickness of 1½" and about
3½" wide on the left and right sides of the mounting
base running the full length of the ManaBloc. (See
illustration below.) The 2x4s will be used to secure the
distribution lines at the correct height as they exit the
ManaBloc. (Support clamps not to exceed 6" spacing
from end of ports.)
4"- 6"
90°
3. Attach the mounting base to the structure in a
suitable location. (See “12.2 Location” on Page
27.) The base should be mounted so the top of
the ManaBloc is between four feet and six feet from
the oor but may be at any height provided that the
height maintains accessibility to all the ports on the
ManaBloc.
4. The mounting base must be rmly attached to a
structure solid enough to support, at a minimum,
the weight of the ManaBloc lled with water. The
base should be square and level.
22½"
Longer
than
ManaBloc
2x42x4
22½"
Longer
than
ManaBloc
2x42x4
MANABLOC
®
5. Center the ManaBloc on the base both vertically and
horizontally, as shown here. Attach the ManaBloc to
the mounting base with four ½" or longer drywall or
wood screws through the holes in the plastic brackets
on the ManaBloc. DO NOT OVERTIGHTEN.
6. As the distribution lines are connected to the
ManaBloc (see “14.3 Connecting distribution lines
to the ManaBloc” on Page 38), ensure that the
tubing exits the unit at a 90° angle to the center
line of the ManaBloc so as not to induce bending
stress on the ManaBloc.
7. When attaching the distribution line tubing to the
2x4 supports, be sure to use appropriately sized
Viega tubing clamps. (For example, use part
number 52000 for " tubing and part number
52020 for ½" tubing.)
Use one clamp per tube to ensure that the tubing
is held securely. Position clamps NO FARTHER
than 6" from the end of the port. DO NOT pull
tubing tight.