Advantix bathroom drain Instructions for Use Model 4936.3 Year built: from 01/2008 en_INT https://tm.by Интернет-магазин TM.
Advantix bathroom drain https://tm.by Интернет-магазин TM.
Table of contents Table of contents 1 2 3 Advantix bathroom drain https://tm.by Интернет-магазин TM.by About these instructions for use 4 1.1 1.2 1.3 Target groups 4 Labelling of notes 4 About this translated version 5 Product information 6 2.1 Standards and regulations 6 2.2 2.2.1 2.2.2 2.2.3 2.3 2.3.1 2.3.2 2.3.3 2.4 2.4.1 2.4.2 2.
About these instructions for use 1 About these instructions for use Trade mark rights exist for this document, further information can be found at viega.com/legal. 1.1 Target groups The information in this instruction manual is directed at the following groups of people: n Heating and sanitary professionals and trained personnel n Tilers n Consumers It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product.
About these instructions for use 1.3 About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW). Some passages in the text may refer to technical codes in Europe/ Germany.
Product information 2 Product information 2.1 Standards and regulations The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards.
Product information 2.2 Intended use 2.2.1 Areas of use The drain is designed for small to medium volumes of water, which occur in e. g. residential building. Technical information, see Ä Chapter 2.3.2 „Technical data“ on page 9. The drain with vertical drain socket is suitable for installation in drill holes and can be used in low floor construction heights from 20 mm to 105 mm.
Product information 2.3 Product description 2.3.1 Overview 1 2 3 4 5 6 123456- grate sealing rings removable odour trap top, can be cut to length flange for the application of the conventional sealing base unit There are various articles available under this model number, which differ by the version of the top supplied. Advantix bathroom drain https://tm.by Интернет-магазин TM.by Frame Article No.
Product information 2.3.2 Technical data Nominal width [DN] (drain 50 socket) 2.3.3 Drainage capacity Ä Chapter 2.2.3 „Drainage capacity“ on page 7 Dimensions and installa‐ tion height Ä Chapter 3.1.2 „Installation dimen‐ sions“ on page 15 Water head seal 30 mm Load class K = 300 kg Operating mode Odour trap In most drains, the ingression of sewer gases into rooms with drains is prevented by an odour trap with a water seal.
Product information n The drain is placed over a floor lead-in (e. g. of a drill hole), through which the drainpipe is led. Fig. 2: General mounting example – Drill hole NOTICE! The creation of a floor recess must be agreed with the fol‐ lowing people: – a structural engineer – the on-site fire protection inspector or the specialist engineer for fire protection If necessary, proof of compliance with building code or an expert's report must exist. 2.4.
Product information Conventional sealing The flange of the drain is intended for conventional sealing. To be able to seal the drain conventionally, you require a suitable sealing collar and a clamping ring with which the cuff is secured Ä Chapter 2.5 „Required accessories“ on page 14. Fig.
Product information Bonded sealing To protect against moisture penetration, apply sealing foils, which are to be processed in liquid state, directly below the tiles on screed and walls. The determination of the stress class and the underground as well as the selection of the suitable bonded sealing must be carried out in compliance with the valid standards and regulations, see: Ä „Regula‐ tions from section: Sealing“ on page 6. Bonded sealing can be carried out with the help of a suitable stacking element.
Product information Important note Careful planning is required for professional sealing. In addition, depending on the individual dampness wear class and the type of foun‐ dation, a suitable BS system with a building regulations certificate of suitability must be chosen. Furthermore, the following factors should be taken into account: n Drain or shower channel must be equipped with a special flange, which has an adhesive surface and a width of at least 30 mm.
Product information 2.5 Required accessories Top Advantix tops are available in a number of sizes and variations. You can also only buy an Advantix top frame and then purchase a suitable designer grate separately (see catalogue). Accessories for the conventional sealing If a conventional sealing is to be made, a suitable sealing collar and a clamping ring will be required. You will find a corresponding set in the catalogue (model 4948.31).
Handling 3 Handling 3.1 Assembly information 3.1.1 Important note Before assembly: n Check if the drainage capacity of the drain is sufficient for the arising water volume Ä Chapter 2.2.3 „Drainage capacity“ on page 7. n Check if the installation height of the drain corresponds with the planned floor construction. n Ensure that the required connection line is installed with the neces‐ sary incline to the planned installation location. n If necessary, supply the required accessories Ä Chapter 2.
Handling n if necessary, stacking element for bonded sealing model 4925 n Material for securing the drain 3.2 Assembly 3.2.1 Connecting the drain Connecting to the wastewater system The connection to the wastewater system must be completed before the drain can be installed in the floor construction. Proceed as follows: Requirements: n A pipe to the planned drainage position is already in place for the connection to the wastewater system. n The drainpipe has an internal sealing lip.
Handling Insert yellow protective plugs. NOTICE! Product damage due to improper installation If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied. Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces. 3.2.3 Sealing the drain NOTICE! Product damage due to improper installation If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Handling Insert sealing ring. The sealing ring must lie in the groove between the flange and the screw holes. INFO! The Viega sealing collar has two differently coated sides. One side is coated with bitumen and the other side with EPDM. If the additional sealing takes place with bitumen sealing lanes, the sealing collar must be used with the bitumen side facing upwards. If EPDM sealing lanes are used, the EPDM side must face upwards. Position the sealing collar on the drain.
Handling Bonded sealing Requirements: n The flange is free of heavy soil. n The complete surface of the flange is lined with material and undam‐ aged. Remove protective foil. Apply the bonded sealing on the dry screed and spread to the inner edge of the flange fleece. NOTICE! Observe the bonded sealing manufacturer's instructions for use. Lay the sealing collar into the bonded sealing. Advantix bathroom drain https://tm.by Интернет-магазин TM.
Handling Apply a second layer of bonded sealing onto the sealing collar and, if necessary, onto the floor. 3.2.4 Mounting the top The top with the grate must still be mounted to finish off the mounting of the drain. Proceed as follows: Calculate the height of the floor construction from the edge in the inside of the drain up to the upper edge of the tiles. Starting with the upper edge, transfer the measured height onto the top. Cut the top to the marked height.
Handling Remove yellow protective plug. Place the top into the drain and align according to the tiles. Work the top into the screed or the floor covering. 3.3 Care 3.3.1 Care tips Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the grate and frame. Under no circum‐ stances should scouring agent or scratching objects be used. Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner.
Handling Remove and clean odour trap. Remove and clean odour trap. Clean drain. Replace odour trap. Re-insert grate. 3.4 Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements. Advantix bathroom drain https://tm.by Интернет-магазин TM.