Installation Guide
Table Of Contents
- About this Document
- Disclaimer
- Product Information
- Handling Instructions
- Installation Instructions
- Limited Warranty
- ProPress approved applications
- Minimum distance between press fittings
- ProPress standard jaws clearance requirements
- ProPress standard jaws clearance requirements between tube, wall, and floor
- ProPress compact jaws clearance requirements
- ProPress compact jaws clearance requirements between tube, wall, and floor
- ProPress rings dimensions
- ProPress rings with V1 Actuator clearance requirements
- ProPress rings with V2 Actuator clearance requirements
- ProPress rings with V1 Actuator clearance requirements between tube, wall, and floor
- ProPress rings with V2 Actuator clearance requirements between tube, wall, and floor
- ProPress rings with C1 Actuator clearance requirements between tube, wall, and floor
- ProPress XL-C rings dimensions
- ProPress XL-C rings clearance requirements
- ProPress XL-C rings clearance requirements between tube, wall, and floor
- Minimum distance between existing soldered or brazed fitting and ProPress fitting
- Minimum distance between existing ProPress fitting and soldered or brazed fitting
- Minimum insertion depths for ProPress ½" to 2" fittings
- Insertion depths for ProPress ½" to 2" no-stop couplings
- Insertion depths for ProPress ½" to 2" extended no-stop couplings
- Minimum insertion depths ProPress 2½" to 4" fittings
- Insertion depths for ProPress 2½" to 4" no-stop couplings
Installation Instructions
25 of 44
IM-PP 724607 0320 ProPress
Tube Diameter
(inches)
A minimum
(inches)
A minimum
(mm)
B minimum
(inches)
B minimum
(mm)
½ ¾ 19 1⅝ 41
¾ ⅞ 22 2⅛ 54
1 1 26 2½ 64
1¼ 1⅛ 29 2⅞ 73
1½ 1¾ 45 3½ 89
2 2 51 4⅜ 111
Table 3: ProPress standard jaws clearance requirements
Tube
Diameter
(inches)
A
minimum
(inches)
A
minimum
(mm)
B
minimum
(inches)
B
minimum
(mm)
C
minimum
(inches)
C
minimum
(mm)
½ ⅞ 23 1 ⅜ 35 2 ½ 64
¾ 1 26 1 ½ 38 2 ½ 64
1 1 ⅛ 29 1 ¾ 45 3 76
1 ¼ 1 ¼ 32 2 ¼ 57 3 ⅛ 80
1 ½ 1 ⅞ 48 2 ½ 64 3 ¾ 95
2 2 ⅛ 54 3 ⅛ 80 5 127
Table 4: ProPress standard jaws clearance requirements between tube, wall, and oor
Tube Diameter
(inches)
A minimum
(inches)
A minimum
(mm)
B minimum
(inches)
B minimum
(mm)
½ ¾ 19 2 51
¾
⅞
22 2⅜ 60
1 26 2⅝ 67
1¼ 1⅛ 28 3⅛ 85
Table 5: ProPress compact jaws clearance requirements
Tube
Diameter
(inches)
A
minimum
(inches)
A
minimum
(mm)
B
minimum
(inches)
B
minimum
(mm)
C
minimum
(inches)
C
minimum
(mm)
½ ⅞ 23 1⅜ 35 2½ 64
¾ 1 26 1½ 38 2¾ 70
1 1⅛ 29 1⅝ 41 3 76
1¼ 1⅝ 39 2⅛ 53 3⅜ 85
Table 6: ProPress compact jaws clearance requirements between tube, wall, and oor
A
B
A
B
C
20°
A
B
A
B
C
20°